Re: [f-nsp] MLXe - mix of linecards X2 and M in same chassis
Robert Hass <[email protected]> Thu, 1 Nov 2018 06:23:59 +0100
| Newsgroups | gmane.network.nsp.foundry |
|---|---|
| Message-ID | <CALNfFTF=2Bu8gZ9GopbQeC1tdp1=oQ4boKE25bwNdwEHVYRzjg@mail.gmail.com> |
On Thu, Nov 1, 2018 at 6:09 AM Takahiro Masuda <[email protected]> wrote: > it's not compatible. > > According to below it's possible: https://gtacknowledge.extremenetworks.com/articles/Q_A/How-to-enable-2-Million-routes-on-MLX-platform Quote: "- Users who have a mix of M and X2 cards in the system, need to turn on Netroute only on X2 cards. Thus the CLI is for a given slot." Also some time ago I heard that M linecard can be used together with X/X2 modules without breaking DFZ if M interfaces will be in separate VRF. Rob _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp