Re: [f-nsp] NP egress buffer on CES

"Jörg Kost" <[email protected]> Thu, 28 Mar 2019 09:52:42 +0100
Newsgroups gmane.network.nsp.foundry
Message-ID <[email protected]>
Oh ;-/ - thanks for that info, we will concern a replacement of the 10G 
module.

On 27 Mar 2019, at 15:04, Kevin Cherry wrote:

> In our experience when this happens it due to hardware failing which 
> progressively gets worse over time.  Normally TAC sends us a complete 
> CES with 10G module and we replace the unit.
>
>
> Kevin Cherry | Liberty Utilities  (Missouri) | Telecommunications 
> Engineer
> P: 4176254216 | C: 4173894918 | E: 
> [email protected]<mailto:[email protected]>
> 720 Schifferdecker, Joplin, MO 64801
> VAT#123456
_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp