Re: [rancid] Arista DCS-7150S-24-F
heasley <[email protected]>
| Newsgroups | gmane.network.rancid |
|---|---|
| Message-ID | <[email protected]> |
Wed, Nov 28, 2018 at 09:13:27AM +0100, Михаил: > Hello. I have a lot of such messages: > > - !Power Supply 1: PWR-460AC-F 460W Ok 4 days, 13:36:23 > - !Power Supply 2: PWR-460AC-F 460W Ok 4 days, 13:36:23 > + !Power Supply 1: PWR-460AC-F 460W Ok 4 days, 14:06:22 > + !Power Supply 2: PWR-460AC-F 460W Ok 4 days, 14:06:2 > > - !Power Supply 1: PWR-460AC-F 460W Ok 4 days, 13:06:24 > - !Power Supply 2: PWR-460AC-F 460W Ok 4 days, 13:06:24 > + !Power Supply 1: PWR-460AC-F 460W Ok 4 days, 13:36:23 > + !Power Supply 2: PWR-460AC-F 460W Ok 4 days, 13:36:23 > > Command that produce it is sh environment all, below is full output: > > sh environment all > System temperature status is: Ok > Alert Critical > Temp Setpoint Limit Limit > Sensor Description (C) (C) (C) (C) > ------- ----------------------------------- ------- ----------- ------ --------- > 1 Cpu temp sensor 39.8 (N/A) N/A 95 100 > 2 Rear temp sensor 32.8 (N/A) N/A 65 75 > 3 Board temp sensor 29.6 (N/A) N/A 55 65 > 4 Front-panel temp sensor 27.5 (N/A) N/A 55 65 > 5 Board temp sensor 31.4 (N/A) N/A 75 85 > 6 FM6000 temp sensor 35.9 (N/A) N/A 92 100 > > PowerSupply 1: > Alert Critical > Temp Setpoint Limit Limit > Sensor Description (C) (C) (C) (C) > ------- ----------------------------------- ------- ----------- ------ --------- > 1 Power supply sensor 26.0 (N/A) N/A 60 70 > > PowerSupply 2: > Alert Critical > Temp Setpoint Limit Limit > Sensor Description (C) (C) (C) (C) > ------- ----------------------------------- ------- ----------- ------ --------- > 1 Power supply sensor 29.0 (N/A) N/A 60 70 > > System cooling status is: Ok > Ambient temperature: 27C > Airflow: port-side intake > Config Actual Speed Stable > Fan Status Speed Speed Uptime Stability Uptime > -------------- ------ ------ ------ ---------------- --------- ---------------- > 1/1 Ok 90% 88% 4 days, 16:44:35 Stable 4 days, 16:44:17 > 2/1 Ok 90% 88% 4 days, 16:44:35 Stable 4 days, 16:44:17 > 3/1 Ok 90% 90% 4 days, 16:44:35 Stable 4 days, 16:44:17 > 4/1 Ok 90% 90% 4 days, 16:44:35 Stable 4 days, 16:44:15 > PowerSupply1/1 Ok 90% 89% 4 days, 16:44:13 Stable 4 days, 16:43:24 > PowerSupply2/1 Ok 90% 89% 4 days, 16:44:13 Stable 4 days, 16:43:24 > > Power Input Output Output > Supply Model Capacity Current Current Power Status Uptime > ------ ----------- -------- ------- ------- ------ ------ ---------------- > 1 PWR-460AC-F 460W 0.33A 4.75A 55.0W Ok 4 days, 16:44:13 > 2 PWR-460AC-F 460W 0.30A 4.62A 55.0W Ok 4 days, 16:44:13 > Total -- 920W -- -- 110.0W -- -- > > How can i get rid of it? Thanks :) please try rancid 3.8; i think it is fixed there. > Mit freundlichen Grüßen, Mikhail. Ebenso. _______________________________________________ Rancid-discuss mailing list [email protected] http://www.shrubbery.net/mailman/listinfo/rancid-discuss