Re: Question of cannot receive messages about 10 seconds

John Schultz <[email protected]> Fri, 19 Oct 2012 09:07:17 -0400
Newsgroups gmane.network.spread.user
Message-ID <[email protected]>
Kyle,

Spread is working as designed here.  On a fast, well-behaved, single segment LAN, then you should be able to safely reduce all the membership timers (set near the top of membership.c) by a factor of 10.

Cheers!

-----
John Lane Schultz
Spread Concepts LLC
Phn: 301 830 8100
Cell: 443 838 2200

On Oct 18, 2012, at 11:29 PM, Kyle Hsieh (謝名凱) wrote:

Hello, Spread team!
 
I have a technical question about Spread toolkit.
 
Here is my spread.conf:
Spread_Segment  192.168.127.255:4803 {
        "192.168.127.1"  192.168.127.1
        "192.168.127.2"  192.168.127.2
        "192.168.127.3"  192.168.127.3
}
 
Each computer runs a spread daemon for sending/receiving messages with each other.
However, if one computer unplugs it’s network cable, the others cannot send and receive messages about 10 seconds.
 
Is this a known issue, or is it by design?
Is there any configuration to shorten the timeout?
 
Thanks for reading!
 
Best regards,
Kyle Hsieh
 
================================================================
Industrial Video Networking (IVN) Division / Software R&D Department
Moxa Inc.
Fl.4, No.135, Lane 235, Baoqiao Rd. Xindian Dist., New Taipei City, Taiwan, R.O.C.
Tel: +886-2-89191230 Ext. 1673
[email protected]
================================================================

_______________________________________________
Spread-users mailing list
[email protected]
http://lists.spread.org/mailman/listinfo/spread-users
smime.p7s (application/pkcs7-signature, 3.7 KB) - not displayed