VNC not working on MSI install
Steve Nutbeen <[email protected]>
| Newsgroups | gmane.network.tight-vnc.general |
|---|---|
| Message-ID | <CAO_h6kwtvZCvPU_5QiHfZUnymLqU0LNkBjuKOTZK6th68vnRkg@mail.gmail.com> |
Hi. We use TightVNC in our software to share part of it with customers. We deploy our software installation through both ClickOnce and MSI builds. We use port 5900 as standard. We have a German client that has installed both versions. In the ClickOnce version, VNC works fine. However, in the MSI version, VNC does not work. In the MSI version I can see port 5900 starting up in netstat but it never gets past status 'WARTEND' (as it is a German machine): TCP 127.0.0.1:5900 VDL001851DE:0 ABHÖREN TCP 127.0.0.1:5900 VDL001851DE:49269 WARTEND I'm not 100% sure which status this is meant to be but the end user does not see the software shared area. I've tried various things like checking port rules, switching off firewalls, running the software as admin, changing folder permissions etc but nothing works. It could be the client's network but I'd think any network settings preventing data connections over the port would affect the ClickOnce version of the software as well. The software is essentially the same, just installed in different locations on the PC. Running the WinVNC exe on ClickOnce the WinVNC log file normally has this data; Thu May 12 15:07:25 2016 vncServer.cpp: trying port number 5900 Thu May 12 15:07:26 2016 vncSockConnect.cpp: started socket connection thread Thu May 12 16:09:42 2016 WallpaperUtils.cpp: unable to fetch Active Desktop options:80004001 vncMenu.cpp: quitting from WM_DESTROY WinVNC.cpp: shutting down server vncServer.cpp: shutting down server object vncSockConnect.cpp: quitting socket connection thread vncServer.cpp: shutting down server object(4) but running on the MSI version I get this; Fri May 13 09:42:11 2016 vncServer.cpp: trying port number 5900 Fri May 13 09:42:12 2016 vncSockConnect.cpp: started socket connection thread Fri May 13 09:42:22 2016 vncSockConnect.cpp: accepted connection from 127.0.0.1 vncClient.cpp: client connected : 127.0.0.1 (id 1) vncClient.cpp: performing VNC authentication VideoDriver.cpp: vncVideoDriver::CheckVersion: ESC_QVI not supported by this version of Mirage vncService.cpp: SelectHDESK failed to close old desktop 5c, error=170 vncServer.cpp: failed to initialize desktop object vncDesktop.cpp: failed to ReleaseDC(m_hrootdc) WallpaperUtils.cpp: unable to fetch Active Desktop options:80004001 Fri May 13 09:42:32 2016 WallpaperUtils.cpp: unable to fetch Active Desktop options:80004001 vncMenu.cpp: quitting from WM_DESTROY WinVNC.cpp: shutting down server vncServer.cpp: shutting down server object vncSockConnect.cpp: quitting socket connection thread vncServer.cpp: shutting down server object(4) Would welcome any suggestions on what to look at next! Steve ------------------------------------------------------------------------------ Mobile security can be enabling, not merely restricting. Employees who bring their own devices (BYOD) to work are irked by the imposition of MDM restrictions. Mobile Device Manager Plus allows you to control only the apps on BYO-devices by containerizing them, leaving personal data untouched! https://ad.doubleclick.net/ddm/clk/304595813;131938128;j ___________________________________________________________ TightVNC mailing list, [email protected] To change your subscription or to UNSUBSCRIBE, please visit https://lists.sourceforge.net/lists/listinfo/vnc-tight-list