Things we missed on Saturday
Felix Kersting <[email protected]> Sun, 17 Dec 2006 23:17:55 -0800
| Newsgroups | gmane.org.clubs.gobiodiesel.mixmasters |
|---|---|
| Message-ID | <[email protected]> |
Friends, Thinking about some of the items we discussed on Saturday.... 1. We agreed that blending High and Low FFA oil would be a good thing to do after our process tolerances are established. We didn't leave any room for that in the feedstock tank layout.... we might want to think about that before we get too carried away. We may need to do a push to characterize our feedstock so we can sort and mix on the way to preheat. We may need to look into a band heater for the oil storage tote as well. We may also be able to use the feedstock tote to do that - we can mix 150 gal of oil in the tote and use the same chemistry in all 3 batches we react, then mix the 150 gal while the first in reacting... what say you all? 2. There was rain water in the oil collection tank (more than Pete wanted to admit to!). Before we start using that tank, we should consider putting a drain in the bottom for water. Seth's big objection to using old heating oil tanks was that there was all sorts of crud in the bottom and if you ever got it out, the bottom was rusted because there had been water sitting there. I see the same thing happening to our oil collection tank. We might want to consider a 1" tap for a heater element as well. Thanks again for everyone's help on Saturday - great results. Felix