Re: [siteplan] Site Update
Felix Kersting <[email protected]> Sun, 07 Jan 2007 23:02:22 -0800
| Newsgroups | gmane.org.clubs.gobiodiesel.mixmasters |
|---|---|
| Message-ID | <[email protected]> |
Friends, My 2 cents worth on Ron's observations; R Buckner wrote: Happy New Year to all! Here are a few items for thought about the site. - We're testing the wvo metal holding tank by loading it with oil. The tank is now plumbed to a plastic tote for distribution. The metal tank has screens to filter the oil. These screens will have to been cleaned periodically. Watch to see that the oil is flowing to the bottom of the tank. The holes from the upper level to the lower level are about an 1” and can get clogged if solids get through the screening Kevin had suggested tossing a tarp over the tank to keep the oil dry. I originally dismissed this idea, but I think we need to keep this tank dry, so the tarp seems like the way to go. - - The processors are being insulated with household fiberglass insulation. This material might be problematic in the future. Didn't we have some other material in mind for insulating? Plus, the fiberglass fibers have a tendency to get in the air. We talked about using R-Max or some sort of rigid foam insulation. Fiberglass will be a mess in a very little time. We need to use the rigid material we origianlly talked about. Greg R was going to bring some nylon banding to hold it in place while latex caulk dried. Let's go with what we discussed. - We need new seals for the processor lids. - Are there any objections to separating the plumbing on the processors to make them independent of each other? The original idea was to make 100 gallons at a time. Our present resources are limited to 50 gallons of preheated wvo, therefore our limit for each processing. We have discussed this before - we intend to make a single batch in each reactor since we can only make enough methoxide for one 50 gal batch. All the processors will be plumbed independently so if one is down, the rest are still functional. - An inline heater for the wash tank has been installed. It is in the experimental stage. Per Zac's comments, this worked great! Good move guys! - The micron sock fuel filter needs some thought and action on how and where to mount it. We probably want to locate it in the pipe between the dryer and the distribution tote. We will also need a water separator on the outlet of the fuel tote - this should be less than $100. - There is 50 gallons of mayonaise being preheated in the conex to evaporate the water. This mayo is really nice. Flows like milk. Shall we go ahead and process all or some of this 50 gallons? When the seals are installed in the lids, and insulation of the processors is finished, we can continue making fuel. Reprosessing the mayo should be a priority, but secondary to making sure fuel is coming down the line. After the water is separated from the mayo, it can be reprosessed with WVO. Note that the water won't evaporate, it will settle to the bottle of the water heater and will need to be drained off, as is done with raw WVO before processing.s Thanks, Felix _______________________________________________ mixmasters mailing list [email protected] http://lists.gobiodiesel.org/mailman/listinfo/mixmasters