Those power supplies are gold in a post eskomolyptic world with battery backed essential services, but eskom is confident there no problems. Well other than the 57b zar bailout .. This year. My point is they perfect for car battery / inverters to a 224 volt supply, to backup systems. If your load to the step up inverter/transformer is 12 volt + .6 volts via a diode that runs from the power supply. You also have a single marine battery supplying 12.4 volts via a diode to the same load. While ac powerered supply is active , the battery is latent unless there is no ac then battery takes over instantly since no more resistance, or is at a lower voltage. To keep battery charged a diode and a resister is run from the ac supplied 12.6v power to the battery using a diode and resistor to keep power flowing at a certain voltage, 12.4 v to prevent overcharging and keep battery charged, while not interfering with primary power supply. In summary ac supplied 12.6 v is fed straight into the load of target device. With a resistor and another diode 12.4 and below is fed to the battery as well. When battery discharges it's kept topped up at 12.4v. Primary ac dips below 12.4 battery takes over. Immune to brownouts as well. You will need to do some math to figure out carried load amperage fuses etc but it's the gist. The voltages I used are just for reference, you will need a voltmeter. Its a lot more fun than buying a ups which are ironically doing a lot better job of what I described above, but useless after half a year. Just my input Daniel On 21 May 2014 4:41 PM, "Saul" <[email protected]> wrote: > > > Hi All, > > This might sound like a strange post but... > > > A while back we did a large install of numbers AP, the result is that > we now have a few large boxes of power supplies that we don't need. > > OUTPUT 12V 1A > > > Option 1 is to simply put them in the bin, but that isn't very eco > friendly > > Option 2: Ideas anyone? > > > Is there anyone that would want such a thing? > > > > > Regards, > > > > > > Saul Stein > > Technical Manager > > Phone: > > +27 (0)21 421 9857 > > Fax: > > +27 (0)21 425 4537 > > Cell: > > +27 (0)82 908 5553 > > Email: > > [1][email protected] > > Web: > > [2]www.enetworks.co.za > > eNetworks > > where service is everything > > A Datacentrix company > > > > eNetworks > > | > > PO Box 2534 > > | > > Cape Town > > | > > South Africa > > | > > 8000 > > 2013 HP GOLD Specialist > > References > > 1. mailto:[email protected] > 2. http://www.enetworks.co.za/ > > _______________________________________________ > IOZ mailing list > [email protected] > http://lists.internet.org.za/mailman/listinfo/ioz > _______________________________________________ IOZ mailing list [email protected] http://lists.internet.org.za/mailman/listinfo/ioz