[Bug 297337] nvme: timeouts and resets with Intel DC P3700

[email protected]
Newsgroups gmane.os.freebsd.bugs
Message-ID <[email protected]/bugzilla/>
https://bugs.freebsd.org/bugzilla/show_bug.cgi?id=297337

--- Comment #5 from Warner Losh <[email protected]> ---
Thanks for the tests and extra information. This tells me we're not chasing a
startup issue, but there's something going on that's triggering the drives to
become unresponsive. After a few seconds is likely quickly enough that we can
start a dtrace script and then let the scrub start. This should tell us if the
drive has stopped responding (my best theory) or if there's some weird bug in
the storage stack we're hitting. I'm on vacation this week, but I'll create a
good nvme dtrace script to see what layer is going amiss and to gather some
data about changing workloads. ZFS is different between 15 and 16, and it may
be scheduling more / different I/O now that's triggering the drives. The fact
that it happens to both either means we're triggering the same firmware bug, or
that we've started scheduling more than 30 seconds of I/O at a time or some
other weird thing.

-- 
You are receiving this mail because:
You are the assignee for the bug.
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.