svn commit: r48724 - head/de_DE.ISO8859-1/books/handbook/geom

Bjoern Heidotting <[email protected]>
Newsgroups gmane.os.freebsd.devel.cvs.doc
Message-ID <[email protected]>
Author: bhd
Date: Sat Apr 23 23:00:32 2016
New Revision: 48724
URL: https://svnweb.freebsd.org/changeset/doc/48724

Log:
  Update to r44663:
  
  Put RAID3 chapter before Software RAID Devices chapter.
  
  While here, fix sect1 name and a acronym case.

Modified:
  head/de_DE.ISO8859-1/books/handbook/geom/chapter.xml

Modified: head/de_DE.ISO8859-1/books/handbook/geom/chapter.xml
==============================================================================
--- head/de_DE.ISO8859-1/books/handbook/geom/chapter.xml	Sat Apr 23 22:56:06 2016	(r48723)
+++ head/de_DE.ISO8859-1/books/handbook/geom/chapter.xml	Sat Apr 23 23:00:32 2016	(r48724)
@@ -5,7 +5,7 @@
 
      $FreeBSD$
      $FreeBSDde$
-     basiert auf: r44662
+     basiert auf: r44663
 -->
 <chapter xmlns="http://docbook.org/ns/docbook" xmlns:xlink="http://www.w3.org/1999/xlink" version="5.0" xml:id="geom">
   <info><title>GEOM: Modulares Framework zur
@@ -880,9 +880,197 @@ mountroot&gt;</screen>
     </sect2>
   </sect1>
 
-  <sect1 xml:id="geom-raid">
+  <sect1 xml:id="geom-raid3">
+    <info>
+
+      <title><acronym>RAID</acronym>3 - Byte-Level Striping mit
+	dedizierter Parität</title>
+
+      <authorgroup>
+	<author>
+	  <personname>
+	    <firstname>Mark</firstname>
+	    <surname>Gladman</surname>
+	  </personname>
+	  <contrib>Geschrieben von </contrib>
+	</author>
+	<author>
+	  <personname>
+	    <firstname>Daniel</firstname>
+	    <surname>Gerzo</surname>
+	  </personname>
+	</author>
+      </authorgroup>
+      <authorgroup>
+	<author>
+	  <personname>
+	    <firstname>Tom</firstname>
+	    <surname>Rhodes</surname>
+	  </personname>
+	  <contrib>Basierend auf Dokumentation von </contrib>
+	</author>
+	<author>
+	  <personname>
+	    <firstname>Murray</firstname>
+	    <surname>Stokely</surname>
+	  </personname>
+	</author>
+      </authorgroup>
+      <authorgroup>
+	<author>
+	  <personname>
+	    <firstname>Björn</firstname>
+	    <surname>Heidotting</surname>
+	  </personname>
+	  <contrib>Übersetzt von </contrib>
+	</author>
+      </authorgroup>
+    </info>
+
+    <indexterm>
+      <primary><acronym>GEOM</acronym></primary>
+    </indexterm>
+    <indexterm>
+      <primary>RAID3</primary>
+    </indexterm>
+
+    <para><acronym>RAID</acronym>3 ist eine Methode, die mehrere
+      Festplatten zu einem einzigen Volume mit einer dedizierten
+      Paritätsfestplatte kombiniert.  In einem
+      <acronym>RAID</acronym>3-System werden die Daten in einzelne
+      Bytes aufgeteilt und dann über alle Laufwerke,
+      mit Ausnahme der Paritätsfestplatte, geschrieben.  Beim Lesen
+      von Daten in einer <acronym>RAID</acronym>3 Implementierung
+      werden alle Festplatten im Array parallel genutzt.  Die Leistung
+      kann durch den Einsatz von mehreren Controllern weiter erhöht
+      werden.  Ein <acronym>RAID</acronym>3-Array hat eine
+      Fehlertoleranz von 1 Laufwerk und bietet dabei eine Kapazität
+      von 1 - 1/n der Gesamtkapazität der Laufwerke im Array, wobei
+      n die Anzahl der Festplatten im Array darstellt.  So eine
+      Konfiguration ist meistens für die Speicherung von größeren
+      Dateien geeignet, wie beispielsweise Multimediadateien.</para>
+
+    <para>Mindestens 3 Festplatten sind erforderlich, um ein
+      <acronym>RAID</acronym>3 zu erstellen.  Jede Festplatte muss
+      von der gleichen Größe sein, da die
+      <acronym>I/O</acronym>-Anfragen für Lesen oder Schreiben
+      auf mehreren Festplatten parallel stattfinden.  Aufgrund der
+      Beschaffenheit von <acronym>RAID</acronym>3, muss die Anzahl der
+      Laufwerke 3, 5, 9, 17 bzw. 2^n + 1 sein.</para>
+
+    <para>Dieser Abschnitt beschreibt, wie ein Software
+      <acronym>RAID</acronym>3 auf einem &os;-System erstellt
+      wird.</para>
+
+    <note>
+      <para>Obwohl es theoretisch möglich ist &os; von einem
+	<acronym>RAID</acronym>3-Array zu booten, wird von solch
+	einer ungewöhnlichen Konfiguration dringend abgeraten.</para>
+    </note>
+
+    <sect2>
+      <title>Ein dediziertes <acronym>RAID</acronym>3-Array
+	erstellen</title>
+
+      <para>In &os; wird die Unterstützung für
+	<acronym>RAID</acronym>3 über die
+	<acronym>GEOM</acronym>-Klasse &man.graid3.8; implementiert.
+	Zum Erstellen eines dedizierten
+	<acronym>RAID</acronym>3-Arrays sind folgende Schritte
+	erforderlich.</para>
+
+      <procedure>
+	<step>
+	  <para>Laden Sie zunächst das Modul
+	    <filename>geom_raid3.ko</filename> mit einem der folgenden
+	    Befehle:</para>
+
+	  <screen>&prompt.root; <userinput>graid3 load</userinput></screen>
+
+	  <para>oder:</para>
+
+	  <screen>&prompt.root; <userinput>kldload geom_raid3</userinput></screen>
+	</step>
+
+	<step>
+	  <para>Stellen Sie sicher, dass ein geeigneter Mountpoint
+	    existiert.  Dieser Befehl erstellt ein neues Verzeichnis,
+	    welches als Mountpoint verwendet werden kann:</para>
+
+	  <screen>&prompt.root; <userinput>mkdir <replaceable>/multimedia</replaceable></userinput></screen>
+	</step>
+
+	<step>
+	  <para>Bestimmen Sie die Gerätenamen der Festplatten, die dem
+	    Array hinzugefügt werden und erstellen Sie ein neues
+	    <acronym>RAID</acronym>3 Gerät.  Das letzte aufgeführte
+	    Gerät wird als dediziertes Paritätslaufwerk verwendet.
+	    Dieses Beispiel verwendet drei unpartionierte
+	    <acronym>ATA</acronym>-Platten:
+	    <filename><replaceable>ada1</replaceable></filename> und
+	    <filename><replaceable>ada2</replaceable></filename> für
+	    die Daten, sowie
+	    <filename><replaceable>ada3</replaceable></filename> für
+	    die Parität.</para>
+
+	  <screen>&prompt.root; <userinput>graid3 label -v gr0 /dev/ada1 /dev/ada2 /dev/ada3</userinput>
+Metadata value stored on /dev/ada1.
+Metadata value stored on /dev/ada2.
+Metadata value stored on /dev/ada3.
+Done.</screen>
+	</step>
+
+	<step>
+	  <para>Partitionieren Sie das neu erstelle Gerät
+	    <filename>gr0</filename> und erstellen Sie darauf
+	    ein <acronym>UFS</acronym>-Dateisystem:</para>
+	
+	  <screen>&prompt.root; <userinput>gpart create -s GPT /dev/raid3/gr0</userinput>
+&prompt.root; <userinput>gpart add -t freebsd-ufs /dev/raid3/gr0</userinput>
+&prompt.root; <userinput>newfs -j /dev/raid3/gr0p1</userinput></screen>
+
+	  <para>Viele Zahlen rauschen nun über den Bildschirm und
+	    nach einer gewissen Zeit ist der Vorgang abgeschlossen.
+	    Das Volume wurde erstellt und kann jetzt in den
+	    Verzeichnisbaum eingehangen werden:</para>
+
+	  <screen>&prompt.root; <userinput>mount /dev/raid3/gr0p1 /multimedia/</userinput></screen>
+
+	  <para>Das <acronym>RAID</acronym>3-Array ist nun
+	    einsatzbereit.</para>
+	</step>
+      </procedure>
+
+      <para>Weitere Konfigurationsschritte sind erforderlich, um die
+	Einstellungen nach einem Systemneustart zu erhalten.</para>
+
+      <procedure>
+	<step>
+	  <para>Das Modul <filename>geom_raid3.ko</filename> muss
+	    geladen werden, bevor das Array eingehangen werden kann.
+	    Damit das Kernelmodul automatisch beim Systemstart geladen
+	    wird, muss die folgende Zeile in
+	    <filename>/boot/loader.conf</filename> hinzugefügt
+	    werden:</para>
+
+	  <programlisting>geom_raid3_load="YES"</programlisting>
+	</step>
+
+	<step>
+	  <para>Die folgenden Informationen über das Volume müssen in
+	    <filename>/etc/fstab</filename> hinzugefügt werden, um
+	    das Dateisystem des Arrays automatisch beim Systemstart
+	    zu aktivieren:</para>
+
+	  <programlisting>/dev/raid3/gr0p1	/multimedia	ufs	rw	2	2</programlisting>
+	</step>
+      </procedure>
+    </sect2>
+  </sect1>
+
+  <sect1 xml:id="geom-graid">
     <info>
-      <title>Software RAID</title>
+      <title>Software <acronym>RAID</acronym></title>
 
       <authorgroup>
 	<author>
@@ -1217,194 +1405,6 @@ raid/r0  OPTIMAL  ada0 (ACTIVE (ACTIVE))
     </sect2>
   </sect1>
 
-  <sect1 xml:id="geom-raid3">
-    <info>
-
-      <title><acronym>RAID</acronym>3 - Byte-Level Striping mit
-	dedizierter Parität</title>
-
-      <authorgroup>
-	<author>
-	  <personname>
-	    <firstname>Mark</firstname>
-	    <surname>Gladman</surname>
-	  </personname>
-	  <contrib>Geschrieben von </contrib>
-	</author>
-	<author>
-	  <personname>
-	    <firstname>Daniel</firstname>
-	    <surname>Gerzo</surname>
-	  </personname>
-	</author>
-      </authorgroup>
-      <authorgroup>
-	<author>
-	  <personname>
-	    <firstname>Tom</firstname>
-	    <surname>Rhodes</surname>
-	  </personname>
-	  <contrib>Basierend auf Dokumentation von </contrib>
-	</author>
-	<author>
-	  <personname>
-	    <firstname>Murray</firstname>
-	    <surname>Stokely</surname>
-	  </personname>
-	</author>
-      </authorgroup>
-      <authorgroup>
-	<author>
-	  <personname>
-	    <firstname>Björn</firstname>
-	    <surname>Heidotting</surname>
-	  </personname>
-	  <contrib>Übersetzt von </contrib>
-	</author>
-      </authorgroup>
-    </info>
-
-    <indexterm>
-      <primary><acronym>GEOM</acronym></primary>
-    </indexterm>
-    <indexterm>
-      <primary>RAID3</primary>
-    </indexterm>
-
-    <para><acronym>RAID</acronym>3 ist eine Methode, die mehrere
-      Festplatten zu einem einzigen Volume mit einer dedizierten
-      Paritätsfestplatte kombiniert.  In einem
-      <acronym>RAID</acronym>3-System werden die Daten in einzelne
-      Bytes aufgeteilt und dann über alle Laufwerke,
-      mit Ausnahme der Paritätsfestplatte, geschrieben.  Beim Lesen
-      von Daten in einer <acronym>RAID</acronym>3 Implementierung
-      werden alle Festplatten im Array parallel genutzt.  Die Leistung
-      kann durch den Einsatz von mehreren Controllern weiter erhöht
-      werden.  Ein <acronym>RAID</acronym>3-Array hat eine
-      Fehlertoleranz von 1 Laufwerk und bietet dabei eine Kapazität
-      von 1 - 1/n der Gesamtkapazität der Laufwerke im Array, wobei
-      n die Anzahl der Festplatten im Array darstellt.  So eine
-      Konfiguration ist meistens für die Speicherung von größeren
-      Dateien geeignet, wie beispielsweise Multimediadateien.</para>
-
-    <para>Mindestens 3 Festplatten sind erforderlich, um ein
-      <acronym>RAID</acronym>3 zu erstellen.  Jede Festplatte muss
-      von der gleichen Größe sein, da die
-      <acronym>I/O</acronym>-Anfragen für Lesen oder Schreiben
-      auf mehreren Festplatten parallel stattfinden.  Aufgrund der
-      Beschaffenheit von <acronym>RAID</acronym>3, muss die Anzahl der
-      Laufwerke 3, 5, 9, 17 bzw. 2^n + 1 sein.</para>
-
-    <para>Dieser Abschnitt beschreibt, wie ein Software
-      <acronym>RAID</acronym>3 auf einem &os;-System erstellt
-      wird.</para>
-
-    <note>
-      <para>Obwohl es theoretisch möglich ist &os; von einem
-	<acronym>RAID</acronym>3-Array zu booten, wird von solch
-	einer ungewöhnlichen Konfiguration dringend abgeraten.</para>
-    </note>
-
-    <sect2>
-      <title>Ein dediziertes <acronym>RAID</acronym>3-Array
-	erstellen</title>
-
-      <para>In &os; wird die Unterstützung für
-	<acronym>RAID</acronym>3 über die
-	<acronym>GEOM</acronym>-Klasse &man.graid3.8; implementiert.
-	Zum Erstellen eines dedizierten
-	<acronym>RAID</acronym>3-Arrays sind folgende Schritte
-	erforderlich.</para>
-
-      <procedure>
-	<step>
-	  <para>Laden Sie zunächst das Modul
-	    <filename>geom_raid3.ko</filename> mit einem der folgenden
-	    Befehle:</para>
-
-	  <screen>&prompt.root; <userinput>graid3 load</userinput></screen>
-
-	  <para>oder:</para>
-
-	  <screen>&prompt.root; <userinput>kldload geom_raid3</userinput></screen>
-	</step>
-
-	<step>
-	  <para>Stellen Sie sicher, dass ein geeigneter Mountpoint
-	    existiert.  Dieser Befehl erstellt ein neues Verzeichnis,
-	    welches als Mountpoint verwendet werden kann:</para>
-
-	  <screen>&prompt.root; <userinput>mkdir <replaceable>/multimedia</replaceable></userinput></screen>
-	</step>
-
-	<step>
-	  <para>Bestimmen Sie die Gerätenamen der Festplatten, die dem
-	    Array hinzugefügt werden und erstellen Sie ein neues
-	    <acronym>RAID</acronym>3 Gerät.  Das letzte aufgeführte
-	    Gerät wird als dediziertes Paritätslaufwerk verwendet.
-	    Dieses Beispiel verwendet drei unpartionierte
-	    <acronym>ATA</acronym>-Platten:
-	    <filename><replaceable>ada1</replaceable></filename> und
-	    <filename><replaceable>ada2</replaceable></filename> für
-	    die Daten, sowie
-	    <filename><replaceable>ada3</replaceable></filename> für
-	    die Parität.</para>
-
-	  <screen>&prompt.root; <userinput>graid3 label -v gr0 /dev/ada1 /dev/ada2 /dev/ada3</userinput>
-Metadata value stored on /dev/ada1.
-Metadata value stored on /dev/ada2.
-Metadata value stored on /dev/ada3.
-Done.</screen>
-	</step>
-
-	<step>
-	  <para>Partitionieren Sie das neu erstelle Gerät
-	    <filename>gr0</filename> und erstellen Sie darauf
-	    ein <acronym>UFS</acronym>-Dateisystem:</para>
-	
-	  <screen>&prompt.root; <userinput>gpart create -s GPT /dev/raid3/gr0</userinput>
-&prompt.root; <userinput>gpart add -t freebsd-ufs /dev/raid3/gr0</userinput>
-&prompt.root; <userinput>newfs -j /dev/raid3/gr0p1</userinput></screen>
-
-	  <para>Viele Zahlen rauschen nun über den Bildschirm und
-	    nach einer gewissen Zeit ist der Vorgang abgeschlossen.
-	    Das Volume wurde erstellt und kann jetzt in den
-	    Verzeichnisbaum eingehangen werden:</para>
-
-	  <screen>&prompt.root; <userinput>mount /dev/raid3/gr0p1 /multimedia/</userinput></screen>
-
-	  <para>Das <acronym>RAID</acronym>3-Array ist nun
-	    einsatzbereit.</para>
-	</step>
-      </procedure>
-
-      <para>Weitere Konfigurationsschritte sind erforderlich, um die
-	Einstellungen nach einem Systemneustart zu erhalten.</para>
-
-      <procedure>
-	<step>
-	  <para>Das Modul <filename>geom_raid3.ko</filename> muss
-	    geladen werden, bevor das Array eingehangen werden kann.
-	    Damit das Kernelmodul automatisch beim Systemstart geladen
-	    wird, muss die folgende Zeile in
-	    <filename>/boot/loader.conf</filename> hinzugefügt
-	    werden:</para>
-
-	  <programlisting>geom_raid3_load="YES"</programlisting>
-	</step>
-
-	<step>
-	  <para>Die folgenden Informationen über das Volume müssen in
-	    <filename>/etc/fstab</filename> hinzugefügt werden, um
-	    das Dateisystem des Arrays automatisch beim Systemstart
-	    zu aktivieren:</para>
-
-	  <programlisting>/dev/raid3/gr0p1	/multimedia	ufs	rw	2	2</programlisting>
-	</step>
-      </procedure>
-    </sect2>
-  </sect1>
-
   <sect1 xml:id="geom-ggate">
     <title><acronym>GEOM</acronym> Gate Netzwerkgeräte</title>

_______________________________________________
[email protected] mailing list
https://lists.freebsd.org/mailman/listinfo/svn-doc-all
To unsubscribe, send any mail to "[email protected]"
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.