Re: Four Drive RAID-5 on RAIDFrame Considered Harmful...
"Robert P. Thille" <[email protected]> Tue, 9 Oct 2007 20:22:42 -0700
| Newsgroups | gmane.os.netbsd.devel.performance |
|---|---|
| Message-ID | <[email protected]> |
On Oct 9, 2007, at 6:53 PM, Thor Lancelot Simon wrote: > On Tue, Oct 09, 2007 at 04:59:58PM -0700, Robert P. Thille wrote: >> >> I tracked it down to the problem that 2 and 3 are relatively >> prime :-) >> Given 4 drives in a RAID-5 setup, you get 3 data blocks per raid >> stripe, >> but the filesystem block size Must be a power of 2, so you always >> have >> to write at least one partial stripe. > > No. Examine the "maxcontig" FFS parameter. > maxcontig appears to be obsolete. Looking thru the sources (current from a month or so ago), I don't think it's used by the kernel/ filesystem, and the options mentioned in postings I found in the mailing lists don't seem to exist anymore. Am I missing something? Thanks, Robert -- Robert Thille 7575 Meadowlark Dr.; Sebastopol, CA 95472 Home: 707.824.9753 Office/VOIP: 707.780.1560 Cell: 707.217.7544 [email protected] YIM:rthille http://www.rangat.org/rthille Cyclist, Mountain Biker, Freediver, Kayaker, Rock Climber, Hiker, Geek May your spirit dive deep the blue, where the fish are many and large!