Re: a question about apcupsd
Manuel Bouyer <[email protected]>
| Newsgroups | gmane.os.netbsd.help |
|---|---|
| Message-ID | <[email protected]> |
On Wed, Nov 08, 2006 at 03:53:14PM +0100, Thierry Lacoste wrote: > I think I found the culprit. > > sheliak# apcaccess status > <snip> > DSHUTD : 020 Seconds > <snip> > > 20 seconds is probably not enough for my old Sparc. > > Looking at the eeprom I have > sheliak# apcaccess eeprom > > Valid EPROM values for the SMART-UPS 700 RM > > Config Current Permitted > Description Directive Value Values > =================================================================== > Upper transfer voltage HITRANSFER 253 253 264 271 280 > Lower transfer voltage LOTRANSFER 196 196 188 208 204 > Return threshold RETURNCHARGE 0 00 15 50 90 > Output voltage on batts OUTPUTVOLTS 230 230 240 220 225 > Sensitivity SENSITIVITY H H M L L > Low battery warning LOWBATT 2 02 05 07 10 > Shutdown grace delay SLEEP 20 020 180 300 600 > Alarm delay BEEPSTATE 0 0 T L N > Wakeup delay WAKEUP 0 000 060 180 300 > Self test interval SELFTEST OFF 336 168 ON OFF > > I tried to change the sleep value with > sheliak# apcupsd --configure SLEEP 180 > Attempting to configure UPS ... > > Reading updated UPS configuration ... > > <snip> > DSHUTD : 020 Seconds > <snip> > > Does it come from apcupsd or is it my UPS which doesn't allow eeprom changes? > > Does someone have a workaround? I think you want to change this with apctest (which can change all eeprom settings). From what I remember it's how I did it. -- Manuel Bouyer <[email protected]> NetBSD: 26 ans d'experience feront toujours la difference --