Re: Help! CanoScan LiDE 30 not found by SANE
Thomas Kaepernick <[email protected]>
| Newsgroups | gmane.os.netbsd.help |
|---|---|
| Message-ID | <[email protected]> |
Am Fri, Jan 26, 2007 at 09:57:30PM -0500, schrieb Xihong Yin: > Hi, > > sane-find-scanner can find the scanner on /dev/uscanner0, but don't know > the vendor and the model. output of sane-find-scanner is > > ---------------- > found USB scanner (UNKNOWN vendor and product) at device /dev/uscanner0 > --------------- ... > [plustek] next device is a USB device (0x04A9-0x220E) From my Linux-Box: options for the scanner-modul of the kernel: vendor=0x4a9 product=0x220d /etc/sane.d/plustek.conf # Plustek-SANE Backend configuration file ... [usb] 0x04a9 0x220d device /dev/usb/scanner0 # # options for the previous USB entry # # switch lamp off after xxx secs, 0 disables the feature # (can also be set via frontend) option lampOff 300 # warmup period in seconds, 0 means no warmup, -1 means auto-warmup # (can also be set via frontend) option warmup -1 # 0 means leave lamp-status untouched, not 0 means switch off # on sane_close # (can also be set via frontend) option lOffOnEnd 1 # # options to tweak the image start-position # (WARNING: there's no internal range check!!!) # # for the normal scan area # option posOffX 0 option posOffY 0 # for transparencies option tpaOffX 0 option tpaOffY 0 # for negatives option negOffX 0 option negOffY 0 # # for setting the calibration strip position # (WARNING: there's no internal range check!!!) # -1 means use built in # (can also be set via frontend) option posShadingY -1 option tpaShadingY -1 option negShadingY -1 # # to invert the negatives, 0 disables the feature # option invertNegatives 0 # # to disable the internal sensor speedup function, # 1 disables the feature # option disableSpeedup 0 # # to save/restore coarse calibration data # (can also be set via frontend) option cacheCalData 0 # # use alternate calibration routines # option altCalibration 0 # # for skipping whole calibration step # option skipCalibration 0 # # for skipping entire fine calibration step # coarse calibration is done # option skipFine 0 # # discard the result of the fine white calibration # option skipFineWhite 0 # for replacing the gain values found during coarse # calibration # (can also be set via frontend) option red_gain -1 option green_gain -1 option blue_gain -1 # for replacing the offset values found during coarse # calibration # (can also be set via frontend) option red_offset -1 option green_offset -1 option blue_offset -1 # # for replacing the default lampoff settings, this # works only for CIS devices like CanoScan LiDE20 # (can also be set via frontend) option red_lampoff -1 option green_lampoff -1 option blue_lampoff -1 # # for adjusting the default gamma values # (can also be set via frontend) option redGamma 1.0 option greenGamma 1.0 option blueGamma 1.0 option grayGamma 1.0 # # to enable TPA (EPSON or UMAX, if autodetection fails) # 0 means default behaviour as specified in the internal tables # 1 means enable (needed for UMAX 3450) option enableTPA 0 # # model override functionality, currently only available for # Mustek devices, using NSCs' vendor ID: 0x0400 and # also their product ID: 0x1000 (LM9831) 0x1001 (LM9832) # # mov/PID | 0x1000 | 0x1001 # --------------------------------------- # 0 (default)| BearPaw1200 | BearPaw 2400 # 1 | ignored | BearPaw 1200 # option mov 0 # # and of course the device-name # # device /dev/usbscanner device auto # # to define a new device, start with a new section: # [usb] # Bye Thomas