Re: Help! CanoScan LiDE 30 not found by SANE

Thomas Kaepernick <[email protected]>
Newsgroups gmane.os.netbsd.help
Message-ID <[email protected]>
Am Fri, Jan 26, 2007 at 09:57:30PM -0500, schrieb Xihong Yin:
> Hi,
> 
> sane-find-scanner can find the scanner on /dev/uscanner0, but don't know
> the vendor and the model. output of sane-find-scanner is
> 
> ----------------
> found USB scanner (UNKNOWN vendor and product) at device /dev/uscanner0
> ---------------
...
> [plustek] next device is a USB device (0x04A9-0x220E)

From my Linux-Box:
options for the scanner-modul of the kernel:
vendor=0x4a9 product=0x220d

/etc/sane.d/plustek.conf
# Plustek-SANE Backend configuration file
...
[usb] 0x04a9 0x220d
device /dev/usb/scanner0

#
# options for the previous USB entry
#
# switch lamp off after xxx secs, 0 disables the feature
# (can also be set via frontend)
option lampOff 300

# warmup period in seconds, 0 means no warmup, -1 means auto-warmup
# (can also be set via frontend)
option warmup -1

# 0 means leave lamp-status untouched, not 0 means switch off
# on sane_close
# (can also be set via frontend)
option lOffOnEnd 1

#
# options to tweak the image start-position
# (WARNING: there's no internal range check!!!)
#
# for the normal scan area
#
option posOffX 0
option posOffY 0

# for transparencies
option tpaOffX 0
option tpaOffY 0

# for negatives
option negOffX 0
option negOffY 0

#
# for setting the calibration strip position
# (WARNING: there's no internal range check!!!)
# -1 means use built in
# (can also be set via frontend)
option posShadingY -1
option tpaShadingY -1
option negShadingY -1

#
# to invert the negatives, 0 disables the feature
#
option invertNegatives 0

#
# to disable the internal sensor speedup function, 
# 1 disables the feature
#
option disableSpeedup 0

#
# to save/restore coarse calibration data
# (can also be set via frontend)
option cacheCalData 0

#
# use alternate calibration routines
#
option altCalibration 0

#
# for skipping whole calibration step
#
option skipCalibration 0

#
# for skipping entire fine calibration step
# coarse calibration is done
#
option skipFine 0

#
# discard the result of the fine white calibration
#
option skipFineWhite 0

# for replacing the gain values found during coarse
# calibration
# (can also be set via frontend)
option red_gain   -1
option green_gain -1
option blue_gain  -1

# for replacing the offset values found during coarse
# calibration
# (can also be set via frontend)
option red_offset   -1
option green_offset -1
option blue_offset  -1

#
# for replacing the default lampoff settings, this
# works only for CIS devices like CanoScan LiDE20
# (can also be set via frontend)
option red_lampoff   -1
option green_lampoff -1
option blue_lampoff  -1

#
# for adjusting the default gamma values
# (can also be set via frontend)
option redGamma         1.0
option greenGamma       1.0
option blueGamma        1.0
option grayGamma        1.0

#
# to enable TPA (EPSON or UMAX, if autodetection fails)
# 0 means default behaviour as specified in the internal tables
# 1 means enable (needed for UMAX 3450)
option enableTPA 0

#
# model override functionality, currently only available for
# Mustek devices, using NSCs' vendor ID: 0x0400 and
# also their product ID: 0x1000 (LM9831) 0x1001 (LM9832)
#
# mov/PID    |    0x1000   |   0x1001
# ---------------------------------------
# 0 (default)| BearPaw1200 | BearPaw 2400
# 1          |   ignored   | BearPaw 1200
#
option mov 0

#
# and of course the device-name
#
# device /dev/usbscanner
device auto

#
# to define a new device, start with a new section:
# [usb] 
#

Bye Thomas
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.