Re: NetBSD 4.0 RC2 on Cats
Chris Gilbert <[email protected]> Fri, 12 Oct 2007 23:57:51 +0100
| Newsgroups | gmane.os.netbsd.ports.cats |
|---|---|
| Message-ID | <[email protected]> |
Izumi Tsutsui wrote: > [email protected] wrote: > >> It's probably one of those that de works fine with but tlp doesn't (note >> if the card is in an i386 server it does work with the tlp driver) > > FYI, I used tlp0 on cats for long time: > > tlp0 at pci0 dev 9 function 0: DECchip 21140A Ethernet, pass 2.0 > tlp0: broken MicroWire interface detected; setting SROM size to 1Kb > tlp0: interrupting at irq 8 > tlp0: Ethernet address 00:00:c0:ee:e4:f8 > nsphy0 at tlp0 phy 3: DP83840 10/100 media interface, rev. 0 > nsphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, auto I'm not sure which cards have the problem, but it happens with one of my tlps, but not the other. The symptom is always that tlp doesn't find the phy. Normally with messages like: tlp0: unable to configure MII tlp0: no media found! There are emails about this going back to 2003. However my recent findings are that this issue doesn't happen in the chris-arm-intr-rework branch. I believe the issue is MD, and related to how interrupts and spls work on cats. Thanks, Chris