Re: Free to a good home: 9000/362

Michael Wolfson <[email protected]> Wed, 6 Jul 2011 09:11:09 -0400
Newsgroups gmane.os.netbsd.ports.hp300
Message-ID <[email protected]>
Ah, I hadn't thought of termination.  I assumed that since there's no external SCSI port, HP would've ensured the bus was set up properly.  Seems strange, though, that the only time it fails is when the installation scripts  prepare to install.

Good thought about OpenBSD.  I just sent a message to them.

  -- MW


On Jul 6, 2011, at 8:08 AM, Izumi Tsutsui wrote:

> Just FYI,
> 
>> When I got to the first screen ("Shall we continue"), it hung with:
>> sd0(spc0:0:0:0): illegal request, data = 00 00 00 00 20 00 00 00
>> sd1(spc0:0:2:0): timed out
> 
> Probably termination problem.  I had to enable terminator on SCSI floppy
> when I added an internal SCSI drive into HP362.
> 
> I guess OpenBSD/hp300 guys (miod@?) might also want 362/382 machines.
> 
> ---
> Izumi Tsutsui