Re: new snapshot

"Yves Bodack" <[email protected]>
Newsgroups gmane.os.netbsd.ports.hp700
Message-ID <004e01c20cc4$52d26a40$1f96078d@acid>
Hi!

I just gave it a try but same problem as last time:
> mainbus0 (root)panic: mbattach: cannot map mainbus IO space
but then i took a look at the matrix of reports from Thilo again, and i
recognized geckos with other then 64 mb have had more luck.
so i tried using only 32mb and ... it works right to the nfs boot requests!
so may be, that's a useful hint

ciao yves...

----- Original Message -----
From: "Matt Fredette" <[email protected]>
To: <[email protected]>
Sent: Wednesday, June 05, 2002 4:06 PM
Subject: new snapshot


>
> Hi!  There is a new binary snapshot of NetBSD/hp700 available under:
>
> ftp://ftp.netbsd.org/pub/NetBSD/arch/hp700/snapshot/20020604-1.6A/
>
> Check your local mirror for a copy.
>
> General Notes:
>
> 0.  Again, this whole project started with Michael Shalayeff's
>     OpenBSD/hppa port.  Without his work as the foundation
>     I'd be nowhere.
>
> 1.  This is really, really alpha stuff.  No foolin.  Use at
>     your own risk.  I keep the power to my HP/UX drive
>     disconnected while testing.
>
> 2.  This snapshot has been tested by me on exactly one machine:
>     An HP 9000/715/50 with 48MB of RAM and a serial console.
>     Other people reported success with the previous snapshot on
>     other machines, and this snapshot should also work on them.
>
> 3.  There is no new machine support in this snapshot.  If your
>     machine didn't work with the previous snapshot, it won't
>     work with this one, either... sorry!
>
> 4.  This is very much a netboot/diskless-only snapshot.  There
>     is no support for booting off of disk, or mounting root
>     on a disk.  This will change once I start committing and
>     can work with itohy to incorporate his work in this area.
>
> Known Problems:
>
> 1.  You will see "ie0: receive descriptors out of sync" and
>     "ie0: reset" messages.  While I haven't debugged these yet,
>     I'm pretty sure they're due to a cache coherency issue.
>     This problem does *not* seem to affect system stability,
>     which is why I haven't dealt with it yet.
>
> How To Use It:
>
> Setting up to run diskless is similar to other architectures.
> The hp700 page of the Diskless NetBSD HOW-TO, at:
>
> http://www.netbsd.org/Documentation/network/netboot/intro.hp700.html
>
> should fill in the hp700-specific details.  To set up a serial
> console, see the FAQ entry at:
>
> http://www.netbsd.org/Ports/hp700/faq.html
>
> So try out the snapshot, and report success and failure to the list.
> Thanks!
>
> Matt
>
> --
> Matt Fredette
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.