Re: A180C

Jochen Kunz <[email protected]>
Newsgroups gmane.os.netbsd.ports.hp700
Message-ID <[email protected]>
On Thu, 1 Jul 2004 10:11:05 -0700
Andy Ruhl <[email protected]> wrote:

> Now, part of the reason why I am working on this machine is to make it
> actually work with HP-UX (funny how that works), so I tried to boot it
> into single user mode (via some HP instructions) and it booted, but I
> could not type anything once the # prompt came. I assume some terminal
> setting problem, but strange that the bios (or firmware) worked fine,
> just not the HP os in single user mode?
Maybe HP-UX needs some hardware handshaking. In that case you should use
"loop back hardware handshaking". Make sure that you have a wiring like
this:
3 ------------- 2		TXD / RXD
2 ------------- 3		RXD / TXD
5 ------------- 5		GND

7 -+         +- 7		RTS
8 -+         +- 8		CTS

6 -+         +- 6		DSR
1 -+         +- 1		DCD
4 -+         +- 4		DTR

i.e. connect pin 2 of one connector to pin 3 on the other and vice
versa. Connect pin 5 of one connector to pin 5 on the other. Shorten
pins 7 to 8 and 6 to 1 to 4. (If you want real hardware handshaking
connect pin 7 of one connector to pin 8 on the other and vice versa.)

> Anyway, working on cross building a current kernel on the
> NetBSD/sparc64 machine for hp700 (there's a combination for you) and
> then booting it off the net from the NetBSD/sparc64 machine.
You can not build hp700 on LP64 machines due to bugs in GCC. You will
get internal compiler errors.
-- 


tschüß,
       Jochen

Homepage: http://www.unixag-kl.fh-kl.de/~jkunz/
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.