Re: apm fix for jornada 720
Hernani Marques Madeira <[email protected]>
| Newsgroups | gmane.os.netbsd.ports.hpcarm |
|---|---|
| Message-ID | <[email protected]> |
On Sun, Sep 18, 2005 at 03:37:59PM +0200, Peter Postma wrote: > I noticed that this message[1] indicates that we're interpreting battery > values wrong. I've also found another document[2] which states that > pmdata[2] contains the combined data bits for both batterys and we're > currently ignoring this. > > Bit 0 & 1 = bit 8 & 9 for the main battery and bit 2 & 3 = bit 8 & 9 > for the backup battery. I've checked this and it seems to be true. > > I also noticed that when the main battery is removed, bit 0 & 1 will both > set high. When the backup battery is removed, bit 2 & 3 will both set low. > > The main battery data is usually between 425 and 680 on my j720 but it only > peaks around 680 when AC is online. And what's about the extended battery; is there also a special interpretation needed? -- hernani