Re: Looking for DECstation 3100/2100 or DECsystem 5100
Izumi Tsutsui <[email protected]> Mon, 14 Aug 2017 08:37:40 +0900
| Newsgroups | gmane.os.netbsd.ports.pmax |
|---|---|
| Message-ID | <[email protected]> |
> > Need for re-capping is probable (also because DEC used so many > > "quarternary ammonium salt" caps like Chemi-Con low ESR 105 degC types > > in nearly all their power supplies). > > PMAX's H7821 PSU is indeed badly affected, especially the output filter > Chemi-Con 1800uF/25V SXF parts, however the PSU has its base PCB mounted > upside down and consequently the components leads up, resulting in caps > being safe as long as the box has been stored in its operating orientation > (it's the seal breaking causing these capacitors to fail). Daugthercards > have components mounted sideways, however their caps seem to be fine. Just FYI, I replaced my 5000/125 PSU with ATX one, based on info of this page: http://www.xanthos.se/~joachim/DS-ATX.html (though I don't know PSU pinout for 3100 ones) --- Izumi Tsutsui