Re: PSA: Clock drift and pkgin

Paul Koning <[email protected]>
Newsgroups gmane.os.netbsd.ports.vax
Message-ID <[email protected]>

> On Dec 13, 2023, at 4:52 PM, Mouse <[email protected]> wrote:
> 
>>> But a drift of a couple of % would not be unexpected.
>> Um, yes, it would be unexpected.
>> The crystal spec in that era was 0.01%, [...]
> 
>> If you see a couple % drift, that's definitely not the crystal.
> 
> I'm not so sure.
> 
> My experience is that older machines keep worse time than newer ones,
> even high-quality older machines and cheapo newer ones.  I suspect that
> crystal frequencies drift with time (or perhaps with something that
> tends to correlate positively with time, such as wide temperature
> ranges in storage).

Considering the physics of crystals and the specs of commercial ones,
it's hard to see how they would be much worse than 0.01% even long term.
Maybe FT-243 style, but those aren't used in computers.

> And, whatever the cause, I don't find a couple of percent drift
> surprising in practice.  I once had a machine (I forget what kind) that
> had really good timekeeping, just not at the frequency it was supposed
> to - exactly what I would expect if the crystal were something like
> 5-10 percent out of spec.

If I had such a machine I would definitely blame the software or
hardware for losing clock interrupts, and definitely not the clock
crystal.

Now, if I were looking at a PDP-11 -- which often uses the power line
frequency -- the question would be whether the modern power company
is doing a poor job on the power line frequency.  Apparently the
very tight specs they used to deliver in decades past are no longer
delivered.

	paul
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.