Re: Hardware fault on M3000
[email protected] Sat, 13 Jan 2018 13:55:27 -0600
| Newsgroups | gmane.os.openbsd.sparc |
|---|---|
| Message-ID | <[email protected]> |
> Is this specific to the M3000? Because I run 6.1 on a M4000 without issue > which is nearly identical architecture wise. > IIRC if you do a full xscf reset and get to the initial user setup dialog > you can add field engineer status to any account. I was able to assign the fieldeng and mode privileges to my user after performing a full reset of the XSCF, but trying to use enableservice requires a service password from Oracle support. On the M3000, addboard and deleteboard are not supported, and replacefru only allows me to replace fans and PSUs -- I guess because there is only one system board and it's not considered field-replaceable.