Re: Re: Power supply efficiency on older model Sun equipment

Geoff Blake <[email protected]>
Newsgroups gmane.os.solaris.at-home
Message-ID <[email protected]>
On Mon, 1 Sep 2008, Brian Costello wrote:

> This got me thinking about my setup that runs 24/7 which is a Sunfire
> V100 along with a Cisco 2950 10/100 switch as shown here:
> http://costello.mine.nu/private/mysun.html  . The V100's uptime is 540
> days (today) so reliability is clearly not an issue.
>
> The second V100 is a cold spare and the SS20 and external SCSI drive are
> now decommissioned. I also have an APC Smart UPS 2200 that protects both
> of these and my DSL modem from power outages. I un-plugged the UPS and
> reconnected it with a short extension cable in which I can access the
> individual wires. I used a clamp meter to see how much current it was
> pulling. With everything running it was consuming 2.15A @120V or 258W. I
> figured that the Cisco 2950 was probably pulling a fair share so I
> pulled the plug on it. The reading only went down to 1.95A so the Cisco
> 2950 is consuming about 24W. The V100 only has an 80W power supply and
> based on the system handbook it should only be pulling about 60W based
> on what is in it. Therefore the UPS and DSL modem are pulling about 170W
> which seems hard to believe.
>
> Does anyone have any experience on the power consumption/efficiency of
> UPS's? You could consider me fairly UPS crazy here with 2 PC with their
> own. One on my wireless phone system base station, one on my Wireless
> router & Vonage box, and one on each of my 2 replay TV units. Needless
> to say, power outages are only a problem if they are longer than an hour
> or so.

Is the UPS running warm/hot to the touch? My experience of running
APC UPS's at a low load is that they are not too efficient and run
warm.

If the ADSL modem/router is 'brick' powered, then a guesstimate of
the load can be easily made, mine has a 9V 2A AC output and
allowing 10% transformer loss it will draw ~20W.

I would be inclined to run the APC UPS at as close to full load as
I can for improved efficiency and cater for extended run time by
more batteries (if it will allow them).

Geoff
-- 
    Geoff Blake G8GNZ      located  near  Chelmsford,  Essex,  U.K.
    Please reply to:      geoff(at)palaemon(dot)demon(dot)co(dot)uk
    Using Linux on  Intel & Linux  or NetBSD on Sun Sparc platforms

    Please  avoid  sending  me  Word  or  PowerPoint  attachments.
    See    <http://www.gnu.org/philosophy/no-word-attachments.html>
------------------------------------------------------------------------------

    This  E-mail  and any  attachment(s) are strictly  confidential
    and is intended solely for the addressee(s). If you are not the
    intended recipient please notify <postmaster(at)palaemon.co.uk>
    and the sender by return and permanently delete the message.

    You may not disclose, forward or copy this E-mail or any of its
    attachments to any third party without the prior consent of the
    sender.

------------------------------------------------------------------------------
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.