SVM question
Dariusz Dolecki <[email protected]> Tue, 3 Jul 2012 07:20:19 -0500
| Newsgroups | gmane.os.solaris.managers |
|---|---|
| Message-ID | <CAFJLB9uNbdTGN3wFnXChCQrOfWWaXrn3Mi=XVYs+eh=Hz3wO6A@mail.gmail.com> |
Hi,
I am seeing this on one of our systems.
d100: RAID
State: Needs Maintenance
Invoke: metareplace d100 c1t14d0s2 <new device>
Interlace: 32 blocks
Size: 88388874 blocks (42 GB)
Original device:
Size: 88390720 blocks (42 GB)
Device Start Block Dbase State Reloc Hot Spare
c1t9d0s2 3921 No Okay Yes
c1t10d0s2 3921 No Okay Yes
c1t11d0s2 3921 No Okay Yes
c1t12d0s2 3921 No Okay Yes
c1t13d0s2 3921 No Okay Yes
c1t14d0s2 3921 No Maintenance Yes
There are no hot spares listed. Do I need to physically pull out c1t14d0
and put in another drive?
Thanks in advance