Sun storedge 3320 disk replacement with veritas
Darwin <[email protected]> Thu, 5 Jul 2012 22:27:19 +0530
| Newsgroups | gmane.os.solaris.managers |
|---|---|
| Message-ID | <CAJB2MDgKGkxCHtmefDQ8Jaq0Muwo4vGiqp+Ovo5Mm6Pi5dLSxw@mail.gmail.com> |
hi Gurus,
I have sun v880 server with 3 sun storedge3320 JBOD.OS solaris 8,with
veritas volume manager.one of JBOD disk Got failed,
The vendor replaced the disk, but it is not visible under Operating system.
tried with devfsadm, cfgadm -al, drvconfig.
even tried reboot -- -r.
Now Got a new disk , but still the same. Logged into jbod with sccli and
put show disks, it is showing bad, later i put sccli> scan disk d0.13
so the bad disk become changed the state from bad to FRMT as follows.
sccli> show disks
Ch Id Size Speed LD Status IDs Rev
----------------------------------------------------------------------------
0 0 279.40GB 320MB ld0 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 1034T6CWBR
0 1 279.40GB 320MB ld1 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 0819T4JDL6
0 2 279.40GB 320MB ld2 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 0931T5YYDX
0 3 279.40GB 320MB ld3 ONLINE HITACHI HUS15303BSUN300G PQ02
S/N 28C3ER9A
0 4 279.40GB 320MB ld4 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 1036T6D1PP
0 5 279.40GB 320MB ld5 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 0819T4KQQA
0 8 279.40GB 320MB ld6 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 0936T6BXS3
0 9 279.40GB 320MB ld7 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 0936T6BV9A
0 10 279.40GB 320MB ld8 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 0819T4K35R
0 11 279.40GB 320MB ld9 ONLINE HITACHI HUS15303BSUN300G PQ02
S/N 28C32B7A
0 12 279.40GB 320MB ld10 ONLINE SEAGATE ST330055LSUN300G 0692
S/N 0825T4XAH4
0 13 279.40GB 320MB NONE FRMT SEAGATE ST330055LSUN300G 0692
S/N 1005T6399G
0 15 N/A N/A NONE ABSENT
Now what is the next step to bring it online and bring into Operating
system.fyi it is not under raid, i tried rebuild