SUMMARY: FMdump output

"Richard Cameo" <[email protected]> Fri, 2 Nov 2012 15:04:31 -0000
Newsgroups gmane.os.solaris.managers
Message-ID <[email protected]>
From: Richard Cameo [mailto:[email protected]] 
Sent: 02 November 2012 15:03
To: '[email protected]'
Subject: FW: FMdump output

 

Hi All,

 

We have a Sunfire T200 server giving the following output from fmdump, it
seems to point at a mainboard issue, but if somebody could confirm this
before changing as my searches haven't proved fruitful. I have also attached
prtdiag.

 

 

# fmdump -v -u 7eb3818e-83e5-6b11-de58-89c338c7f939

TIME                 UUID                                 SUNW-MSG-ID

Oct 31 02:05:48.4999 7eb3818e-83e5-6b11-de58-89c338c7f939 SUN4-8000-9J

   25%  fault.io.fire.pci.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2/pcibus=6/pcidev=2/pcifn=0

           Affects: dev:////pci@7c0/pci@0/pci@1/pci@0,2/scsi@2

               FRU:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2/pcibus=6/pcidev=2

          Location: PCIX0

 

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0

           Affects: dev:////pci@7c0/pci@0

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0

           Affects: dev:////pci@7c0/pci@0/pci@1

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2

           Affects: dev:////pci@7c0/pci@0/pci@1/pci@0,2

               FRU: hc:///component=IOBD

          Location: IOBD

 

Oct 31 08:23:19.7202 7eb3818e-83e5-6b11-de58-89c338c7f939 SUN4-8000-9J

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2

           Affects: dev:////pci@7c0/pci@0/pci@1/pci@0,2

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0

           Affects: dev:////pci@7c0/pci@0/pci@1

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0

           Affects: dev:////pci@7c0/pci@0

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pci.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2/pcibus=6/pcidev=2/pcifn=0

           Affects: dev:////pci@7c0/pci@0/pci@1/pci@0,2/scsi@2

               FRU:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2/pcibus=6/pcidev=2

          Location: PCIX0

 

Oct 31 10:08:18.4744 7eb3818e-83e5-6b11-de58-89c338c7f939 SUN4-8000-9J

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2

           Affects: dev:////pci@7c0/pci@0/pci@1/pci@0,2

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0

           Affects: dev:////pci@7c0/pci@0/pci@1

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pciex.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0

           Affects: dev:////pci@7c0/pci@0

               FRU: hc:///component=IOBD

          Location: IOBD

 

   25%  fault.io.fire.pci.device

 

        Problem in:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2/pcibus=6/pcidev=2/pcifn=0

           Affects: dev:////pci@7c0/pci@0/pci@1/pci@0,2/scsi@2

               FRU:
hc://:product-id=SUNW,Sun-Fire-T200:server-id=ULTRA55/ioboar

d=0/hostbridge=0/pciexrc=1/pciexbus=2/pciexdev=0/pciexfn=0/pciexbus=3/pciexd
ev=1

/pciexfn=0/pciexbus=4/pciexdev=0/pciexfn=2/pcibus=6/pcidev=2

          Location: PCIX0

 

# prtdiag -v

System Configuration:  Sun Microsystems  sun4v Sun Fire T200

System clock frequency: 200 MHz

Memory size: 8184 Megabytes

 

================================ Virtual CPUs
================================

 

 

CPU ID Frequency Implementation         Status

------ --------- ---------------------- -------

0      1000 MHz  SUNW,UltraSPARC-T1     on-line  

1      1000 MHz  SUNW,UltraSPARC-T1     on-line  

2      1000 MHz  SUNW,UltraSPARC-T1     on-line  

3      1000 MHz  SUNW,UltraSPARC-T1     on-line  

4      1000 MHz  SUNW,UltraSPARC-T1     on-line  

5      1000 MHz  SUNW,UltraSPARC-T1     on-line  

6      1000 MHz  SUNW,UltraSPARC-T1     on-line  

7      1000 MHz  SUNW,UltraSPARC-T1     on-line  

8      1000 MHz  SUNW,UltraSPARC-T1     on-line  

9      1000 MHz  SUNW,UltraSPARC-T1     on-line  

10     1000 MHz  SUNW,UltraSPARC-T1     on-line  

11     1000 MHz  SUNW,UltraSPARC-T1     on-line  

12     1000 MHz  SUNW,UltraSPARC-T1     on-line  

13     1000 MHz  SUNW,UltraSPARC-T1     on-line  

14     1000 MHz  SUNW,UltraSPARC-T1     on-line  

15     1000 MHz  SUNW,UltraSPARC-T1     on-line  

 

========================= IO Configuration =========================

 

            IO


Location    Type  Slot Path                                          Name
Model   

----------- ----- ---- ---------------------------------------------
------------------------- ---------

IOBD/NET0    PCIE IOBD                /pci@780/pci@0/pci@1/network@0
network-pciex8086,105e          

IOBD/NET1    PCIE IOBD              /pci@780/pci@0/pci@1/network@0,1
network-pciex8086,105e          

IOBD/PCIE    PCIE IOBD                   /pci@780/pci@0/pci@9/scsi@0
scsi-pciex1000,56 LSI,1064E

IOBD/NET2    PCIE IOBD                /pci@7c0/pci@0/pci@2/network@0
network-pciex8086,105e          

IOBD/NET3    PCIE IOBD              /pci@7c0/pci@0/pci@2/network@0,1
network-pciex8086,105e          

IOBD/PCIE1   PCIE    1           /pci@7c0/pci@0/pci@8/SUNW,XVR-300@0
SUNW,XVR-300 SUNW,375-+

IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/isa@2
isa          

IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@5
usb-pciclass,0c0310          

IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@6
usb-pciclass,0c0310          

IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/ide@8
ide-pci10b9,5229          

IOBD/PCIX0   PCIX    0           /pci@7c0/pci@0/pci@1/pci@0,2/scsi@2
scsi-pci1000,30  LSI,1030

 

========================= HW Revisions
=======================================

 

System PROM revisions:

----------------------

OBP 4.25.12 2008/03/23 13:27

 

IO ASIC revisions:

------------------

Location             Path                                          Device
Revision

-------------------- ---------------------------------------------
------------------------------ ---------

IOBD/SAS-SATA-HBA                                  /pci@780
SUNW,sun4v-pci     0

IOBD/SAS-SATA-HBA                            /pci@780/pci@0
pciex10b5,8532.bb   187

IOBD/SAS-SATA-HBA                      /pci@780/pci@0/pci@9
pciex10b5,8532.bb   187

IOBD/IO-BRIDGE                                     /pci@7c0
SUNW,sun4v-pci     0

IOBD/PCI-SWITCH1                             /pci@7c0/pci@0
pciex10b5,8532.bb   187

IOBD/PCI-BRIDGE                /pci@7c0/pci@0/pci@1/pci@0,2
pciex8086,341.9     9

IOBD/GBE0                    /pci@780/pci@0/pci@1/network@0
pciex8086,105e.108e.105e.6     6

IOBD/GBE0                  /pci@780/pci@0/pci@1/network@0,1
pciex8086,105e.108e.105e.6     6

IOBD/GBE1                    /pci@7c0/pci@0/pci@2/network@0
pciex8086,105e.108e.105e.6     6

IOBD/GBE1                  /pci@7c0/pci@0/pci@2/network@0,1
pciex8086,105e.108e.105e.6     6

IOBD/SAS-SATA-HBA               /pci@780/pci@0/pci@9/scsi@0
pciex1000,56.1000.1000.2     2

 

 

 

 

Many Thanks

 

 