Summary: FC disks

Nagy Ákos <[email protected]>
Newsgroups gmane.os.tru64.managers
Message-ID <[email protected]>
Hi all,

Thanks to Nelson Kawumi:

> Run wwidmgr -quickset -udid indentifier
                        ^^^^^^^^^^^^^^^^^
I left this out. I assumed, which I shouldn't, that
without specifying "-udid <id>", the wwidmgr will
"collect" the first four disks with the smallest
value UDIDs. It doesn't.

Thank you again for the answers,
Regards,

Akos Nagy
Hungary

> Original question:
> > 
> > Dear All,
> > 
> > I had to replace a failed CPU main board of an
> > ES40 (not the PCI MB). The machine has a FC disk
> > storage system (HSG80) connected to it. After
> > the replacement, the disks (DGA1 etc.) can not be
> > seen. I've issued "wwidmgr -quickset" without
> > any success. What am I doing wrong? The FC cards
> > haven't been changed, replaced or modified at all,
> > and neither the HSGs.
> > 
> > Many thanks for any help,
> > Regards,
> > 
> > Akos Nagy
> > Hungary
> >
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.