SUMMARY: Failed internal mirrored drive - why didn't server stay up?
"Cohen, Andy" <[email protected]>
| Newsgroups | gmane.os.tru64.managers |
|---|---|
| Message-ID | <[email protected]> |
ORIGINAL QUESTION ================= We have a DS20E running Tru64 5.1 pk6. It is configured with two internal (system) disks that are mirrored by LSM. Overnight one of these two mirrored disks failed. Unfortunately, this brought the system down. Isn't the point have having mirrored drives to prevent a single-point of failure? i.e., shouldn't the system have kept running with just the one good remaining disk? Or am I misunderstanding what LSM does? SUMMARY ======= Not a whole lot of concrete specifics but in general the answer was -- "Yes, but ..." i.e., Yes the server should've stayed up but the fact that it didn't wasn't really a surprise to anyone: +_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_ "I have no experience with LSM, but I have seen SCSI devices fail in such a way as to make the entire SCSI bus unusable. If both mirrors are on this same bus, this is a potential system-killer. No way for me to know if that's what happened in this case." +_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_ "Sorry about your troubles. Maybe the BIOS (SRM console) isn't set up to boot from both disk devices ? This is an easily overlooked prerequisite. I've moved away from LSM because it's too complex, and I got some HP SmartArray 5300A SCSI controllers in stead. Now my disks are mirrored with hot spares by the 5300A without Tru64 ever knowing or caring... The 5300A is a supported configuration on the DS20E." +_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_ "We just had one crash and halt when a data drive (not root) mirror disk failed, so it's no surprise to me that a root drive failure would bring the box down. At least you still have your data, hopefully. We also found out that the system can't write a crash dump when the root drives are LSM, nor can we do an installable backup (which seems to be broken anyway)." +_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_+_ "In principle, having software mirrored disks SHOULD have allowed the system to keep running. HOWEVER, if this is the system disk and it has things like swap on it, the rules may well be different. I do not personally use LSM on my systems, so I haven't taken the time to fully understand how must "fault resistance" it buys you for every configuration and failure scenario. " Two things seemed to have conspired against us: 1) The BIOS/SRM console was not configured to boot from both disk devices. I had to manually set the boot device to the surviving drive. 2) swap was on these drives which seems to have, illogically to me, played at least some role in the inability for the server to stay running. Thanks to: Dr. Thomas Blinn Denise McCracken Ole Holm Nielsen Bluejay Adametz Andy