Summary: Problem with DS-KZPCC-AC and ES40/Tru64 5.1B-PK3

Hummel Thomas <[email protected]>
Newsgroups gmane.os.tru64.managers
Message-ID <[email protected]>
I have to add the following lines to /sys/conf/<HOSTNAME>

bus             i2o0       at *
controller      i2o_bs0    at i2o0      slot  0
device disk     ri0        at i2o_bs0   drive     0
controller      i2o_bs1    at i2o0      slot  0
device disk     ri1        at i2o_bs1   drive     1

config_driver pza

and rebuild a new kernel with
# doconfig -c <HOSTNAME>

Copy it to / and reboot.


Many thanks for all replies.




>Betreff: Problem with DS-KZPCC-AC and ES40/Tru64 5.1B-PK3
>
>Hi Managers,
>
>we have an ES40 (2 x 833Mhz) with 4 GB Ram, Tru64 5.1B-PK3, Alpha Firmware 6.6-19. I installed a DS-KZPCC-AC (Firmware CQ17) and connected it to the internal drive cage DS-610-6D. The 3 x HP 72 GB 10k Hotplug SCSI Drives are configured as a RAIS 5. But neither in /devices/disk nor in the disk-app in CDE are entries of the RAID-Volume.
>
>On console the volume and the controller are shown as follows:
>
>dza517.0.0.2004.1		DZA517 (BSA)
>pza0.0.0.2004.1			I2OA0
>
>
>Any ideas why the volume doesn't appear? Normally dsfmgr have to create the /dev entries at boot time, right? TIA.
>
>
>Best regards,
>Thomas Hummel
>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.