Summary: DEC 3000 model 8-900 error diagnostic message
Kjell Andresen <[email protected]>
| Newsgroups | gmane.os.tru64.managers |
|---|---|
| Message-ID | <[email protected]> |
> Does anybody have a table indicating the trouble "F0" at an old > DEC3000-800s upgraded to DEC3000-900? I did no prolonged hardware testing of the box, but replaced it. It has served us for a long period with little hassle and my spare machines are all gone. Thanks to the following list members: Oisin McGuinness <[email protected]> - sent along some attachments Tom Smith <[email protected]> [email protected] I let Peter summarize: ------------------------------------------------------------------- I have a listing of the Serial ROM LED codes for the DEC 3000 Model 800 which is the successor of the Model 500. For F0 it says to: 1 Verify that there is a secure connection between the system module and the I/O module. Verify that all power cables are connected correctly. 2 Verify that all memory SIMMs are properly installed. Reseat the MMBs and SIMMs if necessary. (This has never helped for me, even though I cleaned off all the years of dust and dirt inside these machines.) 3 Replace system module. 4 Replace I/O module. This, by the way is the solution for all the Fx (Serial ROM) LED codes. In either case, this means your machine is finished unless you have some spare parts that you can cannibalize from something lying around. These bits cost thousands of dollars. -- Kjell