RE: New IC-R5 and R2 Software - an alternative to Icom and Butel !!!!

"Jonathan Webster" <[email protected]>
Newsgroups gmane.recreation.radio.hardware.icomr2
Message-ID <000201c3239c$16e2d2a0$64923e18@2002Dell>
          Just tried it again, but when I click "Buy Now", I get a message
from IE saying "The name on the security certificate is invalid or does not
match the name of the site".  Is this because you are sent to a different
domain when entering purchase information?

 

Jon

 

 

 

-----Original Message-----
From: icr5dotcom [mailto:[email protected]] 
Sent: Sunday, May 25, 2003 5:27 PM
To: [email protected]
Subject: Re: [icomr2] New IC-R5 and R2 Software - an alternative to Icom and
Butel !!!!

 


The certificate appears to be fine, you may have your browser
security settings set incorrectly.

On Sun, May 25, 2003 at 02:44:33PM -0400, Jonathan Webster wrote:
>           My computer gave me some warning about the security certificate
> for the buying section of the site???
> 
>  
> 
> Jon
> 
>  
> 
>  
> 
>  
> 
> -----Original Message-----
> From: IC-R5 Sales [mailto:[email protected]] 
> Sent: Tuesday, April 15, 2003 10:34 PM
> To: [email protected]
> Cc: [email protected]
> Subject: [icomr2] New IC-R5 and R2 Software - an alternative to Icom and
> Butel !!!!
> 
>  
> 
> 
> Thank you steve for the introduction.
> Yes it is true, I now have some brand new IC-R5 and IC-R2 software
> and cables at http://www.ic-r5.com $29.95
> If anyone has any suggestions or recommendations, or if they by
> chance find anything that needs to be fixed in the software please
> do let me know. I would like to consider this software a work in progress
> and I am willing to make improvements to make it the best available.
> I would like to make it as bulletproof as possible.
> 
> I originally had an IC-R2 and decided to try writing software for it.
> I thought if I could get the r2 version going it would be simple
> to make the r5 version. Boy was I wrong. The R5 software turned into
> an almost total rewrite, not to mention a major research and testing
> project, although that has nothing really to do with
> any of you, anyway I think it came out very well.  I would like
> to add more features like importing icr2 icf and exporting, although it
will
> import .icf(r5) and export to comma delimited format already, more
> is always better. I am considering writing software for the R-10 
> or R3 but will have to see how the 2/5 versions work out first. 
> I also hope to offer a software only(no cable)
> option soon but I want to do some more testing before that appears
> on the website to make sure it works with everyone's cables first.
> 
> The quote from the readme.txt below has most of the information about the 
> software but if anyone has any questions I will be happy to try and answer
> them.
> 
> I hope you enjoy the new website and that the software and cable is useful
> to a lot of people not to mention a nice alternative to what is already
> or not already out there.
> 
> [email protected]
> Michael
> 
> On Tue, Apr 15, 2003 at 10:43:43PM +0100, steve.burke wrote:
> > Hi All
> >  
> > At last an alternative to the Icom and long awaited Butel software!!!...
> > look at this. http://www.ic-r5.com/
> >  
> > We all know the limitations of the Icom product and this is still on
> > revision 1.0 even after the R5 has been launched in the UK for some 6
> > months. I read yesterday in one of the R5 groups that Butel are
> > concentrating on another software development.
> >  
> > Maybe this is what we have all been waiting for?
> >  
> > I have just emailed the sales dept, and I must say that their response
> > was 'instantaneous'!! I have often waited 2 days for a reply from Icom,
> > and they didn't even reply to my last mail!!
> >  
> > Their sales dept have provided the following info about the product, to
> > compliment the site above. Have a read and see what you think!!
> >  
> > Software
> >         ---------
> >       This software will load your scanner's memory into a standard data
> > file.
> >       You can then use the editor to edit the settings. After you have
> > the data 
> >       setup the way you want, you save the changes and download that
> > file to the 
> >       scanner.
> >  
> >       Instructions
> >       ------------
> >       When you first start the software you will be asked for your
> > registration
> >       information. Copy and paste this information EXACTLY as it appears
> > in your
> >       confirmation email. Save this email in case you ever need to
> > reinstall.
> >       You will only have to enter this information the first time you
> > run the       
> >       software.
> >  
> >       Connect your Scanner using the correct cable to your computer's
> > serial port.
> >       If you only have a USB port then you will need a USB-Serial
> > adapter.
> >       Plug the 1/8" jack into the earplug/dataport of the scanner. 
> >       
> >       THE FIRST THING YOU SHOULD DO IS MAKE A BACKUP IMAGE OF YOUR
> > SCANNER'S MEMORY!
> >       Click the Read/Write button to open the cloning window. Click the
> > READ button
> >       and follow the instructions to read your scanners current memory.
> >       Save this file. Do not overwrite it. You can edit this file and
> > when you
> >       select SAVE you will be given the option to save to a different
> > name.
> >       Select another name so you will always have an original copy of
> > your
> >       current frequencies. 
> >  
> >       After you have loaded a file to edit using the Load IC5 File
> > button,
> >       select a frequency to edit by clicking on that line and it will
> > appear 
> >       in the editing area. Make your changes there and press UPDATE. 
> >       If you do not press update then the changes will not be saved. 
> >       To change Settings, Scan Edges, Bank Names, or TV Frequencies
> > select the
> >       appropriate tab. 
> >       
> >       When you have finished editing your file select Save IC5 File. You
> > can save
> >       to the same name but it is recommended that you use a new name
> > each time, for
> >       example mycity01-01-2004.icf so you always have a copy of your old
> > data.
> >       You should always keep a copy of your original memory image in
> > case the scanner
> >       memory becomes corrupt.  
> >  
> >       Channels that are not used are also not displayed when turning the
> > tuing dial
> >       in memory mode. These are Blanked out. You can blank out any
> > channel
> >       by selecting Blanked under the Scan/Skip dropdown box for that
> > channel.
> >       You can also restore any channels you have previously blanked out
> > by chnanging
> >       them from Blanked to Scan/Skip/Prog Scan and they will once again
> > appear when
> >       turning the tuning dial.
> >  
> >       The distribution also includes a memory image of the scanner's
> > factory 
> >       default settings with the 100 SWL frequency lists. If you would
> > like to
> >       restore the factory defaults you can use this file.
> >  
> >         Copy/Paste
> >       -----------
> >         Click on any frequency you want to copy and select Copy from the
> > drop down
> >       menu or use Control-C. Then click on any other frequency and
> > select Edit/Paste 
> >       or Control-V
> >  
> >       Special Features
> >       ----------------
> >       Restore cleared memory: When the scanner's memory is cleared it is
> > not actually
> >       wiped out. The channels are all set to be Blanked out and the
> > first two channels
> >       of the first two banks are set to default values. The rest of the
> > channels 
> >       are still there but hidden. 
> >       Using this software you can restore these by loading an image of
> > the memory 
> >       and changing the status from Blanked to another option under the
> > Skip/Scan 
> >       dropdown box.
> >  
> >       ICF Format Files
> >       This software will import .icf format files made FROM THE IC-R5.
> >       This software is not compatible with older .icf format files for
> > the IC-R2
> >       or other models.
> >       IC-R2 files show data that looks like this:
> > gggghghlionggggmgggogkhlipggg
> >       If you have a .icf file with this data it will cause errors on
> > loading.
> >       Do not use those types of .icf files. You can import .icf files
> > for the R5.
> >       Importing of .icf files made from non-US scanners is not
> > recommended as
> >       the data may not be compatible.
> >       To import a file, select Open IC5 File, then from the drop down
> > box select
> >       .icf as the file format or type *.icf and open to display files of
> > .icf type.
> >       You can then click on the files you have or navigate to them.
> >       Files will be saved in the .ic5 format.
> >  
> >       You can export frequencies to a comma delimited text file using
> > the File/Export
> >       option.
> >  
> >         Definition of Options
> >       ---------------------
> >         Read the users manual! There is no substitute for understanding
> > the scanner.
> >       Terms and features are defined in your user manual for the
> > scanner. Specific
> >       options are also available through the TS/SET(hold for 2 seconds)
> > menu on
> >       the scanner.
> >       
> >       Settings:
> >       Dial Select Step - Sets the dial select step for quick frequency
> > settings
> >       Scan Resume Time - The scan restarts after a signal disappears
> >             based on the scan resume time. This can be 0-5 sec or
> > hold(wait until
> >             you turn the dial to resume scanning)
> >       Scan Pause Time - The scan pauses when receiving signals based on
> > the 
> >             scan pause time. This can be 2-20 sec or hold(pause until
> > signal stops)
> >       Program Skip Scan - Toggles the program skip scan on or off.
> > On=specified freq 
> >             are skipped during Full scan, Band Scan or Programmed scan.
> >       Bank Scan - Toggles memory bank scan on or off.
> >       Scan Edge - Selects the scan edge frequencies for a VFO scan.
> >             Options are selected frequencies, between two user
> > programmed
> >             frequencies, or a full scan.
> >       Operation Beep - beeps can be turned off if you want the unit
> > quiet.
> >       Display Backlight - The backlight can be on, off, or auto which
> > stays on for 5
> >             seconds when a switch or dial is operated.
> >       Auto Power Off - automatically turn off after specified time of no
> > operation.
> >       Power Save - power save on and off
> >       Monitor Switch Function - sticky switch function. When set to
> > sticky
> >             each push of SQL toggles the monitor function on and off.
> > Otherwise
> >             the SQL switch must be pushed and held to function.
> >       Dial Speed Acceleration - The dial speed accelerates automatically
> >             when you turn it rapidly. This can be enabled or disabled.
> >       Lock Function Effect - Sets the accessable switches while the lock
> > function is
> >             ON. You may want some switches available even when the unit
> > is locked
> >             for adjustments of volume etc.
> >       Channel Indication Mode - Turns the channel indication mode on or
> > off.
> >             Note: when on Expand mode must be on. When Off Expand mode 
> >             must also be off. Turning Expand Mode off will turn Chn Ind
> > mode off.
> >       Expand Mode - Turns on additional menu features when holding
> > TS/SET key down
> >             for 2 seconds.
> >       FM/AM Antenna: Select whether using an internal or external
> > antenna.
> >       Weather Alert: Turns weather alert on or off for the current
> > weather channel.
> >       LCD Contrast: Adjusts the contrast of the display.
> >       RF Attenuator: Attenuates input when input can overpower the
> > reciver.
> >       Display Type: Select the default information to show on the
> > screen,
> >             Frequency, Channel Number, Channel Name, Bank Name
> >       Name: You can assign a name to each frequency. Names are limited
> > to
> >             six characters using only upper case A-Z, 0-9, () * +- , / |
> > and space.
> >             You can enter other characters in the software but they will
> > not appear
> >             on the display.
> >       Func+Up/Dn: This setting selects how fast frequencies change when
> > you
> >             hold Function and use the frequency up/down feature(knob or
> > buttons).
> >  
> >  
> >       Scan Edges
> >       This section defines the upper and lower search ranges. A is the
> > lower range
> >       and B is the upper range. You can find the letter by the channel
> > number
> >       for example 001A is the lower range and 002B is the upper range.
> > 003A is
> >       the lower range for the next pair and 004B is the upper range. You
> > can easily
> >       set the desired upper and lower values here. See your scanner
> > manual
> >       for information on using the Search feature.
> >  
> >  
> >       Problems and Solutions
> >       ----------------------
> >       If you have trouble communicating with your scanner or you get a
> > message
> >       saying "Unable to Locate Interface Cable" it is more than likely a
> > problem with
> >       the com port. Try another com port(com2) or another
> > computer(laptop or
> >       a neighbors) to determine if the port is not working. All cables
> > are tested
> >       at several points during and after manufacture to verify they are
> > working.
> >       It is extremely unlikely that the cable itself is bad.
> >       Make sure you have selected the correct Com port in the options.
> >       9600bd is the default baud rate for the scanner and should not be
> > changed.
> >       
> >       Make sure your BIOS settings for your com port are set to the
> > correct
> >       irq/io values. If it is set to AUTO it may not work, some people
> > have had
> >       problems with the computer not activating the port on bootup with
> > the
> >       AUTO setting. Also make sure you have selected the correct com
> > port number,
> >       some computers mislabel com ports on the back of the box.
> >       You can test the com port with another serial device such as a
> > mouse to
> >       verify that the port itself is working.
> >  
> >       If you have anything that starts at bootup like PalmOS sync
> > software
> >       which uses the com port, disable it too.
> >       If you have Quicken installed with the background download manager
> > or
> >       a similar program you may need to disable that.
> >       An "mrtRate" error is caused by Quicken's background download
> >       manager. Intuit's only suggestion is to disable the BDM from
> > within Quicken.
> >  
> >       CL ERR MESSAGE
> >       If you see a CL ERR message on the scanner, it means there was an
> > error during
> >       the transfer. When you restart the scanner it will automatically
> > 'Clear' the
> >       memory. You will need to re-download the memory image or the image
> > you
> >       saved originally for the scanner(or another image) to restore the
> > channel
> >       contents.
> >       WARNING: Entering frequencies outside of the normal range for the
> > scanner
> >       Will cause write errors. The software will accept any frequency
> > which
> >       gives you the ability to experiment but the scanner will not
> > accept frequencies
> >       too far outside of it's natural range.
> >  
> >       Extended Frequency Range 
> >       The software does restrict the entry of   frequencies to the
> > scanners natural 
> >       limits but you may be able to enter out of spec frequencys and it
> > will
> >       be written to the scanner as you have entered it. Frequencies
> > outside the
> >       default range of 0.150-1309.995 Mhz are filtered however the exact
> > numbers    
> >       are not rounded off like other software. This allows you to enter
> > odd
> >       frequency settings on most units.
> >       WARNING: entering frequencies too far out of the scanners natural
> > range
> >       will cause write errors when attempting to download to the
> > scanner. To
> >       correct the error, go back and correct the frequency.
> >  
> 
> 
> 
> 
> 
> 
> Yahoo! Groups Sponsor
> 
> 
> 
> ADVERTISEMENT
>  
>
<http://rd.yahoo.com/M=231971.3069354.4492417.1728375/D=egroupweb/S=17050631
>
08:HM/A=1540635/R=4/id=noscript/*http:/shop.store.yahoo.com/cgi-bin/clink?pr
>
oflowers2+shopping:dmad/M=231971.3069354.4492417.1728375/D=egroupweb/S=17050
>
63108:HM/A=1540635/R=5/1050472659+http://us.rmi.yahoo.com/rmi/http://www.pro
<http://us.rmi.yahoo.com/rmi/http:/www.pro> 
>
flowers.com/rmi-unframed-url/http://www.proflowers.com/freechocolate/index.c
> fm%3FREF=FCHYahooEgroupsEasterLRECgif> 
> 
>  
>
<http://us.a1.yimg.com/us.yimg.com/a/pr/proflowers2/easter_tulip_300x250_cho
> c.gif> 
> 
> 
>  
>
<http://us.adserver.yahoo.com/l?M=231971.3069354.4492417.1728375/D=egroupmai
> l/S=:HM/A=1540635/rand=223225934> 
> 
> 
> Post message:   [email protected] 
> Subscribe:      [email protected] 
> Unsubscribe:    [email protected] 
> List owner:     [email protected] 
> 
> 
> Your use of Yahoo! Groups is subject to the Yahoo!
> <http://docs.yahoo.com/info/terms/>  Terms of Service. 
> 
> 
> 
> [Non-text portions of this message have been removed]
> 
> 
> 
> Post message:   [email protected] 
> Subscribe:      [email protected] 
> Unsubscribe:    [email protected] 
> List owner:     [email protected] 
>  
> 
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ 
> 
> 
> 






Yahoo! Groups Sponsor


 
<http://rd.yahoo.com/M=251812.3170658.4537139.1512248/D=egroupweb/S=17050631
08:HM/A=1564415/R=0/*http:/www.netflix.com/Default?mqso=60164784&partid=3170
658> 


 
<http://us.adserver.yahoo.com/l?M=251812.3170658.4537139.1512248/D=egroupmai
l/S=:HM/A=1564415/rand=251954140> 


Post message:   [email protected] 
Subscribe:      [email protected] 
Unsubscribe:    [email protected] 
List owner:     [email protected] 


Your use of Yahoo! Groups is subject to the Yahoo!
<http://docs.yahoo.com/info/terms/>  Terms of Service. 



[Non-text portions of this message have been removed]


------------------------ Yahoo! Groups Sponsor ---------------------~-->
Get A Free Psychic Reading! Your Online Answer To Life's Important Questions.
http://us.click.yahoo.com/Lj3uPC/Me7FAA/CNxFAA/ELTolB/TM
---------------------------------------------------------------------~->

Post message:   [email protected] 
Subscribe:      [email protected] 
Unsubscribe:    [email protected] 
List owner:     [email protected] 
 

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.