Re: [PATCH] ocfs2: validate inline dir size in ocfs2_dir_foreach_blk_id
ZhengYuan Huang <[email protected]>
| Newsgroups | dev.linux.lists.ocfs2-devel,org.kernel.vger.linux-kernel |
|---|---|
| Message-ID | <CAOmEq9X2YQpPu81nxnMj2Pr9KsVci7GqjvKf5-e2c4K8Pu-=Cg@mail.gmail.com> |
On Fri, Apr 10, 2026 at 6:03 PM Joseph Qi <[email protected]> wrote: > On 4/10/26 2:22 PM, ZhengYuan Huang wrote: > > [BUG] > > A crafted inline-data directory can set i_size larger than id_count. > > readdir then walks past data->id_data and KASAN reports: > > > > BUG: KASAN: use-after-free in ocfs2_check_dir_entry.isra.0+0x31f/0x370 fs/ocfs2/dir.c:305 > > Read of size 2 at addr ffff8880088f0008 by task syz.0.1936/4656 > > Call Trace: > > ... > > ocfs2_check_dir_entry.isra.0+0x31f/0x370 fs/ocfs2/dir.c:305 > > ocfs2_dir_foreach_blk_id+0x203/0xa70 fs/ocfs2/dir.c:1805 > > ocfs2_dir_foreach_blk fs/ocfs2/dir.c:1933 [inline] > > ocfs2_readdir+0x4ba/0x520 fs/ocfs2/dir.c:1977 > > wrap_directory_iterator+0x9c/0xe0 fs/readdir.c:65 > > shared_ocfs2_readdir+0x29/0x40 fs/ocfs2/file.c:2822 > > iterate_dir+0x276/0x9e0 fs/readdir.c:108 > > __do_sys_getdents64 fs/readdir.c:410 [inline] > > __se_sys_getdents64 fs/readdir.c:396 [inline] > > __x64_sys_getdents64+0x143/0x2a0 fs/readdir.c:396 > > ... > > > > [CAUSE] > > ocfs2_dir_foreach_blk_id() uses i_size_read(inode) as the loop bound > > after reading the inode block. Inline directories are only valid while > > i_size <= le16_to_cpu(data->id_count), but that invariant is never > > checked on read. Once ctx->pos reaches id_count, data->id_data + > > ctx->pos points past the inode block and can land in a freed neighbor > > page. > > > > ocfs2_read_inode_block() has already validated dinode->i_size. > So how it happens for the corrupted in-memory i_size? > > Thanks, > Joseph Thanks, my previous description was inaccurate. The issue is not that inode->i_size becomes corrupted in memory after ocfs2_read_inode_block() validates the dinode. The issue is that the current dinode validation does not check the inline-directory invariant i_size <= id_count. ocfs2_validate_inode_block() does basic dinode validation, but it does not verify that inline directory size fits within id_count. Then ocfs2_populate_inode() / ocfs2_refresh_inode() / ocfs2_refresh_inode_from_lvb() copy that unchecked size into the VFS inode. So the actual problem is an unchecked corrupted on-disk i_size, not a post-validation in-memory corruption. Once such an inode is loaded, readdir can legally reach ocfs2_dir_foreach_blk_id(), which uses i_size_read(inode) as the upper bound. Based on your comment, I think the cleaner fix is to reject such inline directories when the inode is loaded or refreshed, rather than only checking in ocfs2_dir_foreach_blk_id(). I will respin the patch accordingly. Thanks, ZhengYuan Huang