Re: [PATCH 3/5] PCI: sg2042: Add Sophgo SG2042 PCIe driver

ALOK TIWARI <[email protected]>
Newsgroups dev.linux.lists.sophgo,org.infradead.lists.linux-riscv,org.kernel.vger.linux-devicetree,org.kernel.vger.linux-kernel,org.kernel.vger.linux-pci
Message-ID <[email protected]>

On 8/28/2025 7:47 AM, Chen Wang wrote:
> From: Chen Wang <[email protected]>
> 
> Add support for PCIe controller in SG2042 SoC. The controller
> uses the Cadence PCIe core programmed by pcie-cadence*.c. The
> PCIe controller will work in host mode only.
> 
> Signed-off-by: Chen Wang <[email protected]>
> ---
>   drivers/pci/controller/cadence/Kconfig       |  12 ++
>   drivers/pci/controller/cadence/Makefile      |   1 +
>   drivers/pci/controller/cadence/pcie-sg2042.c | 134 +++++++++++++++++++
>   3 files changed, 147 insertions(+)
>   create mode 100644 drivers/pci/controller/cadence/pcie-sg2042.c
> 
> diff --git a/drivers/pci/controller/cadence/Kconfig b/drivers/pci/controller/cadence/Kconfig
> index 666e16b6367f..b1f1941d5208 100644
> --- a/drivers/pci/controller/cadence/Kconfig
> +++ b/drivers/pci/controller/cadence/Kconfig
> @@ -42,6 +42,17 @@ config PCIE_CADENCE_PLAT_EP
>   	  endpoint mode. This PCIe controller may be embedded into many
>   	  different vendors SoCs.
>   
> +config PCIE_SG2042
> +	bool "Sophgo SG2042 PCIe controller (host mode)"
> +	depends on ARCH_SOPHGO || COMPILE_TEST
> +	depends on OF
> +	depends on PCI_MSI
> +	select PCIE_CADENCE_HOST
> +	help
> +	  Say Y here if you want to support the Sophgo SG2042 PCIe platform
> +	  controller in host mode. Sophgo SG2042 PCIe controller uses Cadence
> +	  PCIe core.
> +
>   config PCI_J721E
>   	tristate
>   	select PCIE_CADENCE_HOST if PCI_J721E_HOST != n
> @@ -67,4 +78,5 @@ config PCI_J721E_EP
>   	  Say Y here if you want to support the TI J721E PCIe platform
>   	  controller in endpoint mode. TI J721E PCIe controller uses Cadence PCIe
>   	  core.
> +
>   endmenu
> diff --git a/drivers/pci/controller/cadence/Makefile b/drivers/pci/controller/cadence/Makefile
> index 9bac5fb2f13d..4df4456d9539 100644
> --- a/drivers/pci/controller/cadence/Makefile
> +++ b/drivers/pci/controller/cadence/Makefile
> @@ -4,3 +4,4 @@ obj-$(CONFIG_PCIE_CADENCE_HOST) += pcie-cadence-host.o
>   obj-$(CONFIG_PCIE_CADENCE_EP) += pcie-cadence-ep.o
>   obj-$(CONFIG_PCIE_CADENCE_PLAT) += pcie-cadence-plat.o
>   obj-$(CONFIG_PCI_J721E) += pci-j721e.o
> +obj-$(CONFIG_PCIE_SG2042) += pcie-sg2042.o
> diff --git a/drivers/pci/controller/cadence/pcie-sg2042.c b/drivers/pci/controller/cadence/pcie-sg2042.c
> new file mode 100644
> index 000000000000..fe434dc2967e
> --- /dev/null
> +++ b/drivers/pci/controller/cadence/pcie-sg2042.c
> @@ -0,0 +1,134 @@
> +// SPDX-License-Identifier: GPL-2.0
> +/*
> + * pcie-sg2042 - PCIe controller driver for Sophgo SG2042 SoC
> + *
> + * Copyright (C) 2025 Sophgo Technology Inc.
> + * Copyright (C) 2025 Chen Wang <[email protected]>
> + */
> +
> +#include <linux/kernel.h>
> +#include <linux/of.h>
> +#include <linux/pci.h>
> +#include <linux/platform_device.h>
> +#include <linux/pm_runtime.h>
> +
> +#include "pcie-cadence.h"
> +
> +/*
> + * SG2042 only support 4-byte aligned access, so for the rootbus (i.e. to read

support -> supports

> + * the Root Port itself, read32 is required. For non-rootbus (i.e. to read
> + * the PCIe peripheral registers, supports 1/2/4 byte aligned access, so
> + * directly using read should be fine.
> + *
> + * The same is true for write.
[clip]
> +static int sg2042_pcie_probe(struct platform_device *pdev)
> +{
> +	struct device *dev = &pdev->dev;
> +	struct pci_host_bridge *bridge;
> +	struct cdns_pcie *pcie;
> +	struct cdns_pcie_rc *rc;
> +	int ret;
> +
> +	pcie = devm_kzalloc(dev, sizeof(*pcie), GFP_KERNEL);
> +	if (!pcie)
> +		return -ENOMEM;
> +
> +	bridge = devm_pci_alloc_host_bridge(dev, sizeof(*rc));
> +	if (!bridge) {
> +		dev_err(dev, "Failed to alloc host bridge!\n");
> +		return -ENOMEM;
> +	}
> +
> +	bridge->ops = &sg2042_pcie_host_ops;
> +
> +	rc = pci_host_bridge_priv(bridge);
> +	pcie = &rc->pcie;
First, pcie is allocated and then reassigned to &rc->pcie,
which makes the initial allocation effectively leaked and unnecessary.

> +	pcie->dev = dev;
> +
> +	platform_set_drvdata(pdev, pcie);
> +
> +	pm_runtime_enable(dev);
> +
> +	ret = pm_runtime_get_sync(dev);
> +	if (ret < 0) {
> +		dev_err(dev, "pm_runtime_get_sync failed\n");
> +		goto err_get_sync;
> +	}
> +
> +	ret = cdns_pcie_init_phy(dev, pcie);
> +	if (ret) {
> +		dev_err(dev, "Failed to init phy!\n");
> +		goto err_get_sync;
> +	}
> +
> +	ret = cdns_pcie_host_setup(rc);
> +	if (ret < 0) {
> +		dev_err(dev, "Failed to setup host!\n");
> +		goto err_host_setup;
> +	}
> +
> +	return 0;
> +
> +err_host_setup:
> +	cdns_pcie_disable_phy(pcie);
> +
> +err_get_sync:
> +	pm_runtime_put(dev);
> +	pm_runtime_disable(dev);
> +
> +	return ret;
> +}


Thanks,
Alok
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.