[SPDK] Re: Question about MDTS and MAXH2CDATA for NVMe/TCP target

Harris, James R <james.r.harris at intel.com>
Newsgroups dev.linux.lists.spdk
Message-ID <[email protected]>
Hi Wenhua,


On 5/20/20, 6:14 PM, "Wenhua Liu" <liuw(a)vmware.com> wrote:

    Hi,

    I see in the current implementation, for NVMe/TCP target, both controller MDTS and NVMe/TCP have the same value.

    spdk_nvmf_ctrlr_identify_ctrlr:

           cdata->mdts = spdk_u32log2(transport->opts.max_io_size / 4096);


    nvmf_tcp_icreq_handle:

          ic_resp->maxh2cdata = ttransport->transport.opts.max_io_size;

    On host side, upper layer (which is NVMe/TCP independent) uses MDTS to determine the maximum IO size. But with the current implementation, there can only be H2CData PDU transferred, the R2T mechanism is not fully utilized. Because of this, if the max_io_size  is small, the upper layer has to split large IO coming from application to multiple smaller chunks and send to NVMe/TCP initiator driver. If the max_io_size is large, it may take long time for one PDU to be transferred (I’m not expertized on Network and don’t know what problem can happen).

[Jim] I don't really think splitting the large I/O is a problem.  Both the Linux kernel and SPDK drivers automatically do the splitting on behalf of the upper layer or application. The overhead of the splitting is also minimal, since we are only doing one split per 64KiB (or more).

[Jim] Regarding the PDU size - splitting into payload into multiple PDUs is possible but we haven't seen a need to implement that yet with SPDK. One PDU may take a long time to be transferred, but no longer than if it is broken into multiple PDUs.  In either case, the PDU will be split into multiple network packets based on MTU.

    I found this when I ran fio with blocksize setting to 512KB.  I wanted to test a fix I made for MAXH2CDATA impacts the IO behavior but only saw one H2CData PDU for any IOs.

    In my understanding, the MDTS and the MAXH2CDATA don’t have to be same, making them initialized from different config parameters will give us more flexibility.

[Jim] It may give more flexibility, but it would also make the code more complex. But if you can share performance data that shows a clear advantage to making those values different, it could justify that extra complexity.

Regards,

Jim