Re: Device tree representation of (hotplug) connectors: discussion at ELCE
Herve Codina <[email protected]> Thu, 11 Sep 2025 15:58:42 +0200
| Newsgroups | org.kernel.vger.devicetree-compiler,org.kernel.vger.linux-devicetree,org.kernel.vger.linux-kernel |
|---|---|
| Organization | Bootlin |
| Message-ID | <[email protected]> |
On Thu, 11 Sep 2025 15:08:33 +0200 Geert Uytterhoeven <[email protected]> wrote: > Hi Hervé, > > On Thu, 11 Sept 2025 at 14:45, Herve Codina <[email protected]> wrote: > > On Thu, 11 Sep 2025 17:45:17 +0530 > > Ayush Singh <[email protected]> wrote: > > > On 9/11/25 15:53, Herve Codina wrote: > > > > On Thu, 11 Sep 2025 10:54:02 +0200 > > > > Geert Uytterhoeven <[email protected]> wrote: > > > >> On Thu, 11 Sept 2025 at 10:48, Herve Codina <[email protected]> wrote: > > > >>> The choice to map connA to the type 'foo' connector expected by the addon > > > >>> and the choice to map connB or connC to the type 'bar' connector expected by > > > >>> the addon can only be done at runtime and probably with the help of a driver > > > >>> that have the knowledge of the 3 connectors. > > > >>> > > > >>> I have the feeling that the choice of physical connectors to which the addon > > > >>> board is connected to is a human choice when the board is connected. > > > >> All these choices and decisions apply to single-connector add-on boards, too. > > > >> > > > > Yes, in our use case (me and Luca), each addon has an eeprom, wired exactly the > > > > same on all supported addon, which allows to known the exact addon. Also addon > > > > insertions and removals are detected using some gpios wired to the connector. > > > > > > > > Based on that our specific driver handling our specific connector perform the > > > > following operations on addon insertion detection: > > > > - load a first addon DT to have access to the eeprom > > > > - Read the eeprom to determine the addon type > > > > - load the DT matching with the addon type > > > > > > > > This part is of course connector type specific. I mean having an eeprom with > > > > some encoded addon type values and hotplug detection with gpio is a part of > > > > the contract between the board and the addon (part of connector specification). > > > > > > My usecase is a bit more complicated, since I am trying to model all the > > > available headers on BeagleBoard.org sbcs (particularly PocketBeagle 2 > > > initially) as connectors. However, that still ends up being a single > > > connector which can have multiple addon-boards simultaneously instead of > > > the other way around. > > > > In that case, a connector cannot have the state "free" or "used" handled > > globally by a core part. > > > > IMHO, each connector drivers should handle this kind of state if relevant. > > I mean, in case of "pmods" compatible driver having this state per PMOD > > connector could make sense whereas in "beagle-connector" it doesn't. > > It depends on whether the add-on board has stacking headers, or not ;-) > > > Also, on my side, with my 2-step DT loading, the first loading should not > > consider the connector as 'used'. > > > > All of that is implied by the "contract" between the board and the addon. > > It is connector specific and so should be handled by the specific connector > > driver itself. > > Since stacking boards is a fairly common use case (beagle, rpi), perhaps > it makes sense to have a simple method to re-export / forward a connector? > The alternative would be to re-describe and re-export everything. You re-apply an addon DT on the same connector. You should see the exact same symbols without re-exporting anything. I think that you have to re-export stuff only if, on the addon board itself, you wire some pins from one connector to an other one. +-----------------------------+ | Addon board | +---------+ +--------+ + conn A +-------------------+ conn B + + +--, +--------+ +--------+ +---------+ '--+ device | | | +--------+ | +-----------------------------+ Here the resource available at conn A directly wired to conn B should be re-exported in order to allow another addon connected to conn B to use this signal. Multiple addons with conn A connector stacked should see all symbols exported from the based board related to conn A. Best regards, Hervé