Re: Device tree representation of (hotplug) connectors: discussion at ELCE
Herve Codina <[email protected]> Thu, 18 Sep 2025 10:06:19 +0200
| Newsgroups | org.kernel.vger.devicetree-compiler,org.kernel.vger.linux-devicetree,org.kernel.vger.linux-kernel |
|---|---|
| Organization | Bootlin |
| Message-ID | <[email protected]> |
On Thu, 18 Sep 2025 09:44:09 +0200 Herve Codina <[email protected]> wrote: > Hi David, > > On Thu, 18 Sep 2025 13:16:32 +1000 > David Gibson <[email protected]> wrote: > > ... > > > > > Thoughts above suggest a different direction, but here's what I was > > > > thinking before: > > > > > > > > base board: > > > > > > > > connector { > > > > /export/ "i2c" &i2c0; > > > > }; > > > > > > > > addon: > > > > eeprom@10 { > > > > compatible = "foo,eeprom"; > > > > bus-reg = <&i2c 0x10>; > > > > } > > > > > > > > Or, if the addon had multiple i2c devices, maybe something like: > > > > > > > > board-i2c { > > > > compatible = "i2c-simple-bridge"; > > > > bus-ranges = <&i2c 0 0x3ff>; /* Whole addr space */ > > > > eeprom@10 { > > > > compatible = "foo,eeprom"; > > > > reg = <0x10>; > > > > } > > > > widget@20 { > > > > compatible = "vendor,widget"; > > > > reg = <0x20>; > > > > } > > > > } > > > > > > > > Writing that, I realise I2C introduces some complications for this. > > > > Because it has #size-cells = <0>, ranges doesn't really work (without > > > > listing every single address to be translated). Likewise, because we > > > > always need the parent bus phandle, we can't use the trick of an empty > > > > 'ranges' to mean an identity mapping. > > > > > > > > We could invent encodings to address those, but given the addon with > > > > multiple connectors case provides another incentive for a single > > > > connector to allow adding nodes in multiple (but strictly enumerated) > > > > places in the base device tree provides a better approach. > > > > > > and the "place in base device tree" is the goal of the extension bus. > > > > > > The strict enumeration of nodes enumerated is done by two means: > > > - extension busses at connector level > > > Those extensions are described as connector sub-nodes. > > > The addon DT can only add nodes in those sub-nodes to describe devices > > > connected to the relared extension bus. > > > - export symbols > > > An addon DT can only use symbols exported to reference symbols outside > > > the addon DT itself. > > > > > > Can I assume that bus extensions we proposed (i2c-bus-extension and > > > spi-bus-extension) could be a correct solution ? > > > > Maybe? I prefer the idea of a universal mechanism, not one that's > > defined per-bus-type. > > > > > > Also, IIUC the way bus extension operates is a bit different - nodes > > would be "physically" added under the bus extension node, but treated > > logically as if they go under the main bus. What I'm proposing here > > is something at the actualy overlay application layer that allows > > nodes to be added to different parts of the base device tree - so you > > could add your i2c device under the main i2c bus. > > I think we should avoid this kind of node dispatching here and there in > the base DT. > > We work on decoupling busses wired to a connector and dispatching nodes > looks like this decoupling is ignored. > > IMHO, keeping devices available on an addon board as nodes under the > connector is a real hardware representation. > > Also, at runtime, once an addon board DT is applied, when you look at > your current DT either using /proc/device-tree or some links such as > /sys/bus/devices/.../of_node, the connector and extension bus appear > and clearly identify devices behind the connector. > > > > > That approach does complicate removal, but its not as bad as overlays > > at the moment, because a) it could be limited to adding new nodes, not > > modifying existing ones and b) the connector would specify exactly the > > places that additions are allowed. > > > > I think bus extensions comply with a) and b). > > Yes, bus extensions need to be handled per-bus types but they have the > advantage of keeping the hardware reality well described and visible at > runtime in term of "wiring" topology. > > Whatever the solution, this will already be handled per-bus types. > Only busses that support runtime DT node addition/removal (OF_RECONFIG_* > notifications in the kernel implementation) will support adding or > removing nodes. > > Your approach is more complex, dispatch node here and there and actually > is also a per-bus types solution. > > I think, in order to choose between both solutions, the main question is: > Do we want to dispatch nodes provided by an addon DT everywhere in the base > DT ? > > IMHO, the answer is no. > > Rob, others, any opinion ? > The base DT describes the base board hardware. With this in mind, adding a node at some location other than behind a connector node means that you add a new device on this board and not on something behind a connector. In other words this describes a physical modification of the base board itself. Best regards, Hervé