On Sat, Jul 25, 2026 at 11:58:22PM +0530, Praveen Talari wrote:
> _update_opp_table_clk() uses clk_get(dev, NULL) to acquire the
> device's clock. On platforms where the perf domain device has no
> Linux clock and is instead managed entirely by firmware via
> devm_pm_opp_of_add_table() (through
> of_genpd_add_provider_simple()/onecell()), clk_get() returns
> -ENOENT. That case is treated as valid (the OPP table can still
> have entries sourced from firmware), but opp_table->clk is left
> holding ERR_PTR(-ENOENT) rather than being reset to NULL:
> 
> 	opp_table->clk = clk_get(dev, NULL);
> 	ret = PTR_ERR_OR_ZERO(opp_table->clk);
> 	...
> 	if (ret == -ENOENT) {
> 		opp_table->clk_count = 1;
> 		return opp_table;   /* opp_table->clk is still ERR_PTR(-ENOENT) */
> 	}
> 
> Consumers that only check IS_ERR(opp_table->clk) treat this as a
> valid clk and pass it straight into the clk consumer API. In
> particular, dev_pm_opp_set_rate() calls
> clk_round_rate(opp_table->clk, target_freq), and clk_round_rate()
> only guards against a NULL clk, so it dereferences the error pointer
> to read clk->exclusive_count and crashes:
> 
>   Unable to handle kernel NULL pointer dereference at virtual
>   address 000000000000002e
>   ...
>   pc : clk_round_rate+0x3c/0x188
>   ...
>   Call trace:
>    clk_round_rate+0x3c/0x188 (P)
>    dev_pm_opp_set_rate+0x114/0x33c
> 
> Rather than teaching every clk consumer API to special-case
> ERR_PTR(-ENOENT), fix it at the source: use clk_get_optional()
> instead of clk_get() in _update_opp_table_clk(), which already
> translates -ENOENT into a NULL clk. This documents that the clock is
> genuinely optional for such devices, and keeps opp_table->clk holding
> either a valid clk or NULL, never a lingering -ENOENT error pointer.
> _opp_config_clk_single() is only wired up via opp_table->config_clks
> when a clk was actually found, and every other opp_table->clk
> consumer already tolerates NULL through the standard clk API (which
> treats a NULL clk as a no-op), so no other call site needs to change.
> 
> Suggested-by: Sebastian Reichel <[email protected]>
> Signed-off-by: Praveen Talari <[email protected]>

Reviewed-by: Sebastian Reichel <[email protected]>

Greetings,

-- Sebastian

> ---
> Changes in v2:
> - Switched from guarding clk_round_rate() against error pointers to
>   fixing the root cause in OPP core: use clk_get_optional() instead
>   of clk_get() in _update_opp_table_clk(), so opp_table->clk is left
>   as NULL (not ERR_PTR(-ENOENT)) when a device has no Linux clock,
>   per Sebastian Reichel's review suggestion.
> - Dropped the drivers/clk/clk.c change entirely.
> - Link to v1: https://patch.msgid.link/[email protected]
> ---
>  drivers/opp/core.c | 51 ++++++++++++++++++++++++---------------------------
>  1 file changed, 24 insertions(+), 27 deletions(-)
> 
> diff --git a/drivers/opp/core.c b/drivers/opp/core.c
> index b6966e509f7d..80da241d40f5 100644
> --- a/drivers/opp/core.c
> +++ b/drivers/opp/core.c
> @@ -1591,39 +1591,36 @@ static struct opp_table *_update_opp_table_clk(struct device *dev,
>  	    opp_table->clks)
>  		return opp_table;
>  
> -	/* Find clk for the device */
> -	opp_table->clk = clk_get(dev, NULL);
> +	/*
> +	 * There are few platforms which don't want the OPP core to manage
> +	 * device's clock settings. In such cases neither the platform
> +	 * provides the clks explicitly to us, nor the DT contains a valid
> +	 * clk entry. The OPP nodes in DT may still contain "opp-hz" property
> +	 * though, which we need to parse and allow the platform to find an
> +	 * OPP based on freq later on.
> +	 *
> +	 * This is a simple solution to take care of such corner cases, i.e.
> +	 * make the clk_count 1, which lets us allocate space for frequency
> +	 * in opp->rates and also parse the entries in DT. Use
> +	 * clk_get_optional() instead of clk_get() so opp_table->clk stays
> +	 * NULL for such devices, instead of holding an ERR_PTR(-ENOENT) that
> +	 * consumers must remember to special-case.
> +	 */
> +	opp_table->clk = clk_get_optional(dev, NULL);
>  
>  	ret = PTR_ERR_OR_ZERO(opp_table->clk);
> -	if (!ret) {
> -		opp_table->config_clks = _opp_config_clk_single;
> -		opp_table->clk_count = 1;
> -		return opp_table;
> +	if (ret) {
> +		dev_pm_opp_put_opp_table(opp_table);
> +		dev_err_probe(dev, ret, "Couldn't find clock\n");
> +		return ERR_PTR(ret);
>  	}
>  
> -	if (ret == -ENOENT) {
> -		/*
> -		 * There are few platforms which don't want the OPP core to
> -		 * manage device's clock settings. In such cases neither the
> -		 * platform provides the clks explicitly to us, nor the DT
> -		 * contains a valid clk entry. The OPP nodes in DT may still
> -		 * contain "opp-hz" property though, which we need to parse and
> -		 * allow the platform to find an OPP based on freq later on.
> -		 *
> -		 * This is a simple solution to take care of such corner cases,
> -		 * i.e. make the clk_count 1, which lets us allocate space for
> -		 * frequency in opp->rates and also parse the entries in DT.
> -		 */
> -		opp_table->clk_count = 1;
> -
> -		dev_dbg(dev, "%s: Couldn't find clock: %d\n", __func__, ret);
> -		return opp_table;
> -	}
> +	if (opp_table->clk)
> +		opp_table->config_clks = _opp_config_clk_single;
>  
> -	dev_pm_opp_put_opp_table(opp_table);
> -	dev_err_probe(dev, ret, "Couldn't find clock\n");
> +	opp_table->clk_count = 1;
>  
> -	return ERR_PTR(ret);
> +	return opp_table;
>  }
>  
>  /*
> 
> ---
> base-commit: b4515cf4156356e8f4fe6e0fdc17f59adab9772f
> change-id: 20260723-fix_ptr_check_on_clk-603605c3e350
> 
> Best regards,
> --  
> Praveen Talari <[email protected]>
>
signature.asc (application/pgp-signature, 833 B)
-----BEGIN PGP SIGNATURE-----
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=WAGQ
-----END PGP SIGNATURE-----
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.