[PATCH] hwmon: (pmbus/mp2975) Eliminate dead code

Guenter Roeck <[email protected]>
Newsgroups org.kernel.vger.linux-hwmon
Message-ID <[email protected]>
Coverity reports dead code in mp2975_data2reg_linear11(). Code analysis
shows that the parameter passed to the function is always non-negative.
This means that negative values do not need to be handled, and the
associated variable and conditional code can be removed.

No functional impact or change.

Signed-off-by: Guenter Roeck <[email protected]>
---
 drivers/hwmon/pmbus/mp2975.c | 5 -----
 1 file changed, 5 deletions(-)

diff --git a/drivers/hwmon/pmbus/mp2975.c b/drivers/hwmon/pmbus/mp2975.c
index 5393f7aeea0f..8e5193933ceb 100644
--- a/drivers/hwmon/pmbus/mp2975.c
+++ b/drivers/hwmon/pmbus/mp2975.c
@@ -176,7 +176,6 @@ mp2975_vid2direct(int vrf, int val)
 static u16 mp2975_data2reg_linear11(s64 val)
 {
 	s16 exponent = 0, mantissa;
-	bool negative = false;
 
 	/* simple case */
 	if (val == 0)
@@ -196,10 +195,6 @@ static u16 mp2975_data2reg_linear11(s64 val)
 	/* Convert mantissa from milli-units to units */
 	mantissa = clamp_val(DIV_ROUND_CLOSEST_ULL(val, 1000), 0, 0x3ff);
 
-	/* restore sign */
-	if (negative)
-		mantissa = -mantissa;
-
 	/* Convert to 5 bit exponent, 11 bit mantissa */
 	return (mantissa & 0x7ff) | ((exponent << 11) & 0xf800);
 }
-- 
2.45.2