Re: [PATCH v9 4/6] thermal: khadas-mcu-fan: Add fan config from platform data Add regulator support

[email protected]
Newsgroups org.kernel.vger.linux-i2c,dev.linux.lists.mfd,org.infradead.lists.linux-amlogic,org.infradead.lists.linux-arm-kernel,org.kernel.vger.linux-devicetree,org.kernel.vger.linux-kernel,org.kernel.vger.linux-pm
Message-ID <[email protected]>
On 8/7/26 4:34 AM, Daniel Lezcano wrote:
> On 8/5/26 10:06, Ronald Claveau via B4 Relay wrote:
>> From: Ronald Claveau <[email protected]>
>>
>> Replace the hardcoded MAX_LEVEL constant and fan register
>> with values read from platform_data (fan_reg, levels[] and nlevels),
>> as new MCUs need different values.
>>
>> The cooling device's state is stored as an index into levels[],
>> and khadas_mcu_fan_set_level() writes levels[state] to fan_reg,
>> rather than writing the raw state value as before.
>>
>> Optionally acquire and enable a "fan" regulator supply
>> at probe time and on resume,
>> so boards that gate fan power through a regulator are handled.
>>
>> Reviewed-by: Neil Armstrong <[email protected]>
>> Signed-off-by: Ronald Claveau <[email protected]>
>> ---
> 
>  * Through which tree this patch should go ? (assuming there is a
> dependency on other patches)
> 

I think this patch should go through MFD as this patch depends on it.

>  * How this will behave with 100 levels with the step wise governor ?
> For a 100ms passive delay and 100 states, it will take 10s before
> reaching the full speed

Yes the VIM4 MCU accept values from 0 to 100, but here I'm giving a list
which is (0, 30, 40, 55, 75, 100), so 5 steps to full speed.

-- 
Best regards,