[PATCH v6 2/4] dt-bindings: iio: flow: add Sensirion SLF3S liquid flow sensor
Wadim Mueller <[email protected]>
| Newsgroups | org.kernel.vger.linux-iio,org.kernel.vger.linux-devicetree,org.kernel.vger.linux-kernel |
|---|---|
| Message-ID | <[email protected]> |
Document the bindings for the Sensirion SLF3S family of digital liquid-flow sensors on I2C. The family currently covers the SLF3S-0600F, SLF3S-1300F and SLF3S-4000B variants. All variants share the same register map and differ only in the flow scale factor and the calibrated measurement range, which the driver reads back from the product-information register. Since that lookup is needed in any case, a fallback compatible would buy nothing, so each variant gets its own compatible without a fallback. A future drop-in compatible part can then claim one of these compatibles and work on kernels that do not know its product ID yet. The active calibration medium (water / IPA) is runtime-switchable via the in_volumeflow_medium sysfs attribute and therefore not a DT property. Signed-off-by: Wadim Mueller <[email protected]> --- .../bindings/iio/flow/sensirion,slf3s.yaml | 55 +++++++++++++++++++ MAINTAINERS | 7 +++ 2 files changed, 62 insertions(+) create mode 100644 Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml diff --git a/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml b/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml new file mode 100644 index 000000000000..79718f4f98bd --- /dev/null +++ b/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml @@ -0,0 +1,55 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/iio/flow/sensirion,slf3s.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Sensirion SLF3S liquid flow sensor + +maintainers: + - Wadim Mueller <[email protected]> + +description: + Family of digital liquid-flow sensors from Sensirion with I2C interface. All + family members share the same register map; sub-types differ only in the flow + scale factor and the calibrated measurement range. The sub-type can be + identified from the product-information register. + +properties: + compatible: + enum: + - sensirion,slf3s-0600f + - sensirion,slf3s-1300f + - sensirion,slf3s-4000b + + reg: + maxItems: 1 + + vdd-supply: true + + interrupts: + maxItems: 1 + +required: + - compatible + - reg + - vdd-supply + +additionalProperties: false + +examples: + - | + #include <dt-bindings/interrupt-controller/irq.h> + + i2c { + #address-cells = <1>; + #size-cells = <0>; + + flow-sensor@8 { + compatible = "sensirion,slf3s-0600f"; + reg = <0x08>; + vdd-supply = <®_3v3>; + interrupt-parent = <&gpio0>; + interrupts = <0 IRQ_TYPE_EDGE_RISING>; + }; + }; diff --git a/MAINTAINERS b/MAINTAINERS index ce020ded5fd3..497492825f70 100644 --- a/MAINTAINERS +++ b/MAINTAINERS @@ -24583,6 +24583,13 @@ S: Maintained F: Documentation/ABI/testing/sysfs-bus-iio-chemical-sgp40 F: drivers/iio/chemical/sgp40.c +SENSIRION SLF3S LIQUID FLOW SENSOR DRIVER +M: Wadim Mueller <[email protected]> +R: Maxwell Doose <[email protected]> +L: [email protected] +S: Maintained +F: Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml + SENSIRION SPS30 AIR POLLUTION SENSOR DRIVER M: Tomasz Duszynski <[email protected]> S: Maintained -- 2.52.0