Re: [PATCH v2 10/33] ibmvfc: add logic for protocol specific fabric logins
Dave Marquardt <[email protected]> Wed, 29 Jul 2026 10:24:17 -0500
| Newsgroups | org.ozlabs.lists.linuxppc-dev,org.kernel.vger.linux-kernel,org.kernel.vger.linux-scsi |
|---|---|
| Message-ID | <[email protected]> |
Tyrel Datwyler <[email protected]> writes: > @@ -1530,8 +1538,14 @@ static void ibmvfc_set_login_info(struct ibmvfc_host *vhost) > login_info->max_cmds = cpu_to_be32(max_cmds); > login_info->capabilities = cpu_to_be64(IBMVFC_CAN_MIGRATE | IBMVFC_CAN_SEND_VF_WWPN); > > - if (vhost->mq_enabled || vhost->using_channels) > + if (vhost->mq_enabled || vhost->using_channels) { > login_info->capabilities |= cpu_to_be64(IBMVFC_CAN_USE_CHANNELS); > + if (vhost->nvme_enabled) { > + login_info->capabilities |= cpu_to_be64(IBMVFC_YES_NVMEOF); > + login_info->capabilities |= cpu_to_be64(IBMVFC_YES_SCSI); > + login_info->capabilities |= cpu_to_be64(IBMVFC_CAN_USE_WWPN_ALL); > + } > + } Should setting IBMVFC_YES_SCSI be conditioned on vhost->nvme_enabled? -Dave