Re: Bacula or Drive problem?
"Dr. Thorsten Brandau via Bacula-users" <[email protected]>
| Newsgroups | gmane.comp.bacula.user |
|---|---|
| Message-ID | <[email protected]> |
Udo Kaune schrieb am 13.06.25 um 23:47: > Hi Thorsten, > > Did you reboot the box recently and did by any chance your devices get > reordered? > What does lsscsi -g show and does that correspond to your > bacula-sd.conf entries? > > Best regards, Udo > Hi Udo, yes, I regularily reboot the system for maintenance: sudo lsscsi -g [0:0:0:0] disk Areca ARC-1883-VOL#000 R001 /dev/sda /dev/sg0 [0:0:0:1] disk Areca ARC-1883-VOL#001 R001 /dev/sdb /dev/sg1 [0:0:0:2] disk Areca Data6 R001 /dev/sdc /dev/sg2 [0:0:0:4] disk Areca VOL_Data4 R001 /dev/sdd /dev/sg3 [0:0:16:0] process Areca RAID controller R001 - /dev/sg4 [1:0:0:0] enclosu ATTO VirtualSES 0001 - /dev/sg6 [1:0:1:0] tape IBM ULTRIUM-HH9 R3G1 /dev/st0 /dev/sg7 [1:0:1:1] mediumx BDT FlexStor II 6.21 /dev/sch0 /dev/sg8 That looks very susual and it worked in the last months with sg7 Now, just for the fun of it I used mtx -f /dev/sg8 status additionally and got: mtx: Request Sense: Long Report=yes mtx: Request Sense: Valid Residual=no mtx: Request Sense: Error Code=70 (Current) mtx: Request Sense: Sense Key=Unit Attention mtx: Request Sense: FileMark=no mtx: Request Sense: EOM=no mtx: Request Sense: ILI=no mtx: Request Sense: Additional Sense Code = 2A mtx: Request Sense: Additional Sense Qualifier = 01 mtx: Request Sense: BPV=no mtx: Request Sense: Error in CDB=no mtx: Request Sense: SKSV=no Mode sense (0x1A) for Page 0x1D failed Storage Changer /dev/sg8:1 Drives, 24 Slots ( 0 Import/Export ) Data Transfer Element 0:Full (Storage Element 13 Loaded):VolumeTag = 000050CU Storage Element 1:Full :VolumeTag=000003L9 Storage Element 2:Full :VolumeTag=000006L9 Storage Element 3:Full :VolumeTag=000009L9 Storage Element 4:Full :VolumeTag=000012L9 Storage Element 5:Full :VolumeTag=000002L9 Storage Element 6:Full :VolumeTag=000005L9 Storage Element 7:Full :VolumeTag=000008L9 Storage Element 8:Full :VolumeTag=000011L9 Storage Element 9:Full :VolumeTag=000001L9 Storage Element 10:Full :VolumeTag=000004L9 Storage Element 11:Full :VolumeTag=000007L9 Storage Element 12:Full :VolumeTag=000010L9 Storage Element 13:Empty Storage Element 14:Full :VolumeTag=000021L9 Storage Element 15:Full :VolumeTag=000018L9 Storage Element 16:Full :VolumeTag=000015L9 Storage Element 17:Full :VolumeTag=000023L9 Storage Element 18:Full :VolumeTag=000020L9 Storage Element 19:Full :VolumeTag=000017L9 Storage Element 20:Full :VolumeTag=000014L9 Storage Element 21:Full :VolumeTag=000022L9 Storage Element 22:Full :VolumeTag=000019L9 Storage Element 23:Full :VolumeTag=000016L9 Storage Element 24:Full :VolumeTag=000013L9 As this surprisingly looked more like a changer, despite the error code=70, I changed the changer path in bacula-sd.conf to /dev//sg8 Then I ran a backup (catalogue to make it quick): *And to my surprise - the backup worked again. * Now, this is a big surprise. I would not check the devices if despite many reboots (both, host and changer) all of a sudden the device is not correct. To be honest, that would probably be something I would not have looked into.... Thanks. You made my weekend. Cheers T _______________________________________________ Bacula-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/bacula-users