Re: Bacula or Drive problem?

"Dr. Thorsten Brandau via Bacula-users" <[email protected]>
Newsgroups gmane.comp.bacula.user
Message-ID <[email protected]>

Udo Kaune schrieb am 13.06.25 um 23:47:
> Hi Thorsten,
>
> Did you reboot the box recently and did by any chance your devices get 
> reordered?
> What does lsscsi -g show and does that correspond to your 
> bacula-sd.conf entries?
>
> Best regards, Udo
>
Hi Udo,

yes, I regularily reboot the system for maintenance:

sudo lsscsi -g
[0:0:0:0]    disk    Areca    ARC-1883-VOL#000 R001  /dev/sda   /dev/sg0
[0:0:0:1]    disk    Areca    ARC-1883-VOL#001 R001  /dev/sdb   /dev/sg1
[0:0:0:2]    disk    Areca    Data6            R001  /dev/sdc   /dev/sg2
[0:0:0:4]    disk    Areca    VOL_Data4        R001  /dev/sdd   /dev/sg3
[0:0:16:0]   process Areca    RAID controller  R001  -          /dev/sg4
[1:0:0:0]    enclosu ATTO     VirtualSES       0001  -          /dev/sg6
[1:0:1:0]    tape    IBM      ULTRIUM-HH9      R3G1  /dev/st0   /dev/sg7
[1:0:1:1]    mediumx BDT      FlexStor II      6.21  /dev/sch0  /dev/sg8



That looks very susual and it worked in the last months with sg7

Now, just for the fun of it I used mtx -f /dev/sg8 status additionally 
and got:

mtx: Request Sense: Long Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=70 (Current)
mtx: Request Sense: Sense Key=Unit Attention
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx: Request Sense: ILI=no
mtx: Request Sense: Additional Sense Code = 2A
mtx: Request Sense: Additional Sense Qualifier = 01
mtx: Request Sense: BPV=no
mtx: Request Sense: Error in CDB=no
mtx: Request Sense: SKSV=no
Mode sense (0x1A) for Page 0x1D failed
  Storage Changer /dev/sg8:1 Drives, 24 Slots ( 0 Import/Export )
Data Transfer Element 0:Full (Storage Element 13 Loaded):VolumeTag = 
000050CU
      Storage Element 1:Full :VolumeTag=000003L9
      Storage Element 2:Full :VolumeTag=000006L9
      Storage Element 3:Full :VolumeTag=000009L9
      Storage Element 4:Full :VolumeTag=000012L9
      Storage Element 5:Full :VolumeTag=000002L9
      Storage Element 6:Full :VolumeTag=000005L9
      Storage Element 7:Full :VolumeTag=000008L9
      Storage Element 8:Full :VolumeTag=000011L9
      Storage Element 9:Full :VolumeTag=000001L9
      Storage Element 10:Full :VolumeTag=000004L9
      Storage Element 11:Full :VolumeTag=000007L9
      Storage Element 12:Full :VolumeTag=000010L9
      Storage Element 13:Empty
      Storage Element 14:Full :VolumeTag=000021L9
      Storage Element 15:Full :VolumeTag=000018L9
      Storage Element 16:Full :VolumeTag=000015L9
      Storage Element 17:Full :VolumeTag=000023L9
      Storage Element 18:Full :VolumeTag=000020L9
      Storage Element 19:Full :VolumeTag=000017L9
      Storage Element 20:Full :VolumeTag=000014L9
      Storage Element 21:Full :VolumeTag=000022L9
      Storage Element 22:Full :VolumeTag=000019L9
      Storage Element 23:Full :VolumeTag=000016L9
      Storage Element 24:Full :VolumeTag=000013L9


As this surprisingly looked more like a changer, despite the error 
code=70, I changed the changer path in bacula-sd.conf to /dev//sg8

Then I ran a backup (catalogue to make it quick):

*And to my surprise - the backup worked again. *

Now, this is a big surprise. I would not check the devices if despite 
many reboots (both, host and changer) all of a sudden the device is not 
correct. To be honest, that would probably be something I would not have 
looked into....

Thanks. You made my weekend.

Cheers

T

_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.