Re: IEA304W SYSTEM WAIT STATE CODE 80009064 DURING IEAVNP10 INITIALIZATION
| Newsgroups | gmane.comp.emulators.hercules390.general |
|---|---|
| Organization | DISSEN Software, Bar & Grill - Israel Ltd. |
| Message-ID | <[email protected]> |
Play system programmer. Look for the PSW and registers. On 17 Mar 2019 21:01:01 -0700 "rixhawg-/[email protected] [hercules-390]" <[email protected]> wrote: :>I know that this issue was discussed and closed back in 2016, but after reviewing all of the posts and comments and applying the fixes to the configuration files I am still at a loss. :> :> :> My issue is this. I recently upgraded my workstation from a motherboard that only supported 8gig of memory to one that supports 32gig. It's running an I5 4core Intel cpu running Windows 7 Professional. Both systems have the Hyperion 4.1 version of Hercules and I am using the same configuration file for both systems. On my old 8gig system, my z/OS 1.10 system IPLs fine and I have been running it for a couple of months on the old PC. However, when I run the same exact OS and configuration file on the new 32gig system, I encounter the error mentioned in previous posts. See below for the error: :> :> :> IEA304W SYSTEM WAIT STATE CODE 80009064 DURING IEAVNP10 INITIALIZATION :> :> :> :> I can run the system using Hercules 3.07 fine on the new 32gig PC, but would like to use the latest version. Any ideas? :> :> :> Rick -- Binyamin Dissen <[email protected]> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel Should you use the mailblocks package and expect a response from me, you should preauthorize the dissensoftware.com domain. I very rarely bother responding to challenge/response systems, especially those from irresponsible companies.