Re: IEA304W SYSTEM WAIT STATE CODE 80009064 DURING IEAVNP10 INITIALIZATION
| Newsgroups | gmane.comp.emulators.hercules390.general |
|---|---|
| Message-ID | <MN2PR18MB3038B0C0602FDBC35C8BED06AC470@MN2PR18MB3038.namprd18.prod.outlook.com> |
Correction, I mean CLPA instead of COLD at the IEA101A prompt..
Cliff McNeill
=====================
Look in MVS System Codes manual for wait state 064 where the four bytes have this format
x0rrrwww
where:
x Irrelevant information.
rrr A hexadecimal reason code indicating the reason for the
failure.
www The wait state code.
Under Operator Response for entry code 009 it says to re-IPL specifying a COLD start at the IEA101A enter system parameters prompt.
Cliff McNeill
:>
:>
:> IEA304W SYSTEM WAIT STATE CODE 80009064 DURING IEAVNP10 INITIALIZATION
:>
:>