Why am I getting this HHCCP027E Device 0148 not in configuration...

"Anyanso" <[email protected]>
Newsgroups gmane.comp.emulators.turnkey-mvs
Message-ID <[email protected]>
Hi all,

I have been following the installation and currently struggling to get my MVS TK3 ipl'd but running into the "Device 0148 not in configuration"
problem. I have checked with the cook book ops docs, tried google and whatever else I can find but nothing has been helpful in explaining why and what I am doing wrong and how to fix it. 

The problem: Hercules MVS3.8j is up (see log info below) and telnet connection established. However, according to "Operating the MVS 3.8J Tur(n)key System" document, the next thing should be to issue ipl 148 and I did and the result that I got is shown as follows:

 No SIGABEND handler                                                          +
  Regular Expressions support
  Automatic Operator support
  Machine dependent assists: cmpxchg1 cmpxchg4 cmpxchg8 fetch_dw store_dw
Running on ANYANSO-PKHA40D Windows_NT-5.2 i686 MP=2
HHCHD018I Loadable module directory is hercules
Crypto module loaded (c) Copyright Bernard van der Helm, 2003-20
  Active: Message Security Assist                                              +
          Message Security Assist Extension 1
          Message Security Assist Extension 2
comp=-1,compparm=-1,ra=2,raq=4,rat=2,wr=2,gcint=5,gcparm=0,nostress=0,
        freepend=-1,fsync=0,trace=0,linuxnull=0
HHCHT001I HTTP listener thread started: tid=000009F8, pid=2924
HHCHT013I Using HTTPROOT directory "C:\Program Files\Hercules\root\"
HHCCF065I Hercules: tid=00000BD4, pid=2924, pgid=2924, priority=0
HHCHT006I Waiting for HTTP requests on port 80
HHCSD004I Device 0002 bound to socket localhost:3505
HHCSD020I Socketdevice listener thread started: tid=000009F4, pid=2924
HHCTE001I Console connection thread started: tid=00000A08, pid=2924
HHCTE003I Waiting for console connection on port 3270
** tt32_loaddll: LoadLibraryEx("TunTap32.dll") failed; rc=126: The specified mod
HHCCP002I CPU0000 thread started: tid=00000A94, pid=2924, priority=15
HHCCP003I CPU0000 architecture mode z/Arch
HHCTT002I Timer thread started: tid=00000900, pid=2924, priority=-20
HHCPN001I Control panel thread started: tid=00000BD4, pid=2924
HHCSH049I Shared device 0.1 thread started: tid=000009A0, pid=2924
HHCAO001I Hercules Automatic Operator thread started;
          tid=00000BD8, pri=0, pid=2924
HHCSH057I Waiting for shared device requests on port 3090
HHCTE009I Client 127.0.0.1 connected to 3215 device 0:0009
ipl 148
HHCCP027E Device 0148 not in configuration

                Telnet Connection
Hercules version 3.07 built on Mar 23 2010 01:41:03
running on ANYANSO-PKHA40D (Windows_NT-5.2 i686 MP=2)
Connected to device 0:0009

Here's what my Hercules.cnf looks like:

#
# Hercules Emulator Control file...
# Description: Hercules configuration File
# MaxShutdownSecs: 15
#
#
# System parameters
#

ARCHMODE  z/Arch
CCKD      RA=2,RAQ=4,RAT=2,WR=2,GCINT=5,GCPARM=0,NOSTRESS=0,TRACE=0,FREEPEND=-1
CNSLPORT  3270
CONKPALV  (3,1,10)
CPUMODEL  3090
CPUSERIAL 002623
ECPSVM    NO
HTTPPORT  80 NOAUTH
HTTPROOT  "C:/Program Files/Hercules/root/"
LPARNAME  HERCULES
MAINSIZE  512
MOUNTED_TAPE_REINIT  DISALLOW
NUMCPU    1
OSTAILOR  Z/OS
PANRATE   50
PGMPRDOS  LICENSED
SHCMDOPT  NODIAG8
SHRDPORT  3090
SYSEPOCH  1900
TIMERINT  50
TZOFFSET  -0500
XPNDSIZE  128
YROFFSET  0

HERCPRIO  0
TODPRIO   -20
DEVPRIO   8
CPUPRIO   15

# Card Readers

0001    2501
0002    2501    localhost:3505 sockdev ascii trunc eof

# Card Punches

0003    3525    "C:/Program Files/mvs38j/pch/punch00d.txt" ascii crlf

# Line Printers

0004    3211    "C:/Program Files/mvs38j/prt/print00e.txt" crlf

# Console Printers

0009    3215

# Display Terminals

0010    3270    * 192.168.1.196 255.255.255.0
0011    3270    * 192.168.1.197 255.255.255.0
00C0    3270    * 192.168.1.196 255.255.255.0
00C1-00C2    3270    * 192.168.1.197 255.255.255.0

# CTC Adapters

000E    LCS     192.168.200.2
-------------------------------------------


What could I be doing wrong and how can I go about resolving this problem?

Thanks everyone in advance.
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.