Re: BETA News 10-05-21  --  ALPHA Released

"cedarlakebuzzards" <cedarlakebuzzards-/[email protected]>
Newsgroups gmane.comp.emulators.turnkey-mvs
Message-ID <[email protected]>
The key to solving the problem is to analyze the IEC141I message.  
There usually is a modifier to the code as part of the IEC141I message
(i.e. 013-xx).  The xx gives more details as to why the S013 occurred. 
The rest of the message gives more clues to the problem.

Good Luck
Ed

--- In [email protected], "Carlos Aguilera" <vitoriarest@...>
wrote:
>
> Phil:
>
>
>
> According to the S013 abend this is the explanation I find:
>
>
>
> The error occurred during processing of an OPEN macro instruction.
This
> system completion code is accompanied by message IEC141I. Refer to the
> explanation of message IEC141I for complete information about the task
that
> was ended and for an explanation of the return code in register 15
>
>
>
>
>
> Possible causes for this abend include:
>
>
>
> 1. DCB parameters conflict, no BLKSIZE or not valid multiple of LRECL
>
> 2. Merge - SORTIN01 does not contain the maximum blocksize
>
>
>
> 3. JCL -- tried to create a PDS without allocating directory blocks
>
>
>
> 4. Missing or misplaced SYSIN DD card
>
>
>
> 5. PDS member not found when coded in JCL
>
>
>
>
>
> Carlos Aguilera
>
> 1401 Liggates Rd
>
> Lynchburg VA 24502
>
> Carlos@...
>
> 434-401-4828
>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.