Re: input processing issues

David Sugar <[email protected]>
Newsgroups gmane.comp.gnu.bayonne.devel
Organization GNU Telephony
Message-ID <[email protected]>
I should add "input" normally deals with "line oriented" input; that is, 
something that expects to have some kind of in effect "newline" 
character at the end.  The default is "#".  Collect can also use a exit 
or terminating character, but in the case of collect, it is part of the 
input returned, and when a digit count is fixed, it returns after the 
full count is collected.

David Sugar wrote:
> I think "collect" is what you would normally use for this case.  Read 
> generally deals with parsing dtmf digits that have already been 
> buffered.  You could either use collect in front of read, as in:
> 
>     collect count=8
>     read %myvar count=8 format="????????"
> 
> Or possibly do it in collect itself:
> 
>     collect %myvar count=8 format="????????"
> 
> Although you do not need the format= for this, either, since you are not 
> transforming the data being read.  Format is normally used for things 
> like parsing a date field:
> 
> ????/??/??
> 
> Hence, if the user enters 20050109 the %var will then hold 
> "2005/01/09"...but to just fill a var with digits, format is redundent 
> and unneeded.
> 
> 
> Alexandre BOULANGER wrote:
> 
>> Hi,
>>
>> I have a working IVR application based on Bayonne2 (0.8.8) with SIP
>> support. Nice work, congratulations
>>
>> One annoying thing in my script is input processing. I have a
>>     string.8 %tel_dtmf
>>         input %tel_dtmf count=8 format="????????"
>>
>> statement that retrieves a 8 numbers value; after the 8e value has been
>> entered, there's a 3-4s blank time before the script continues.
>> If I use # as a terminating digit, there's no blank, but I don't want to
>> use such a digit.
>>
>> I tried
>>     string.8 %tel_dtmf
>>     read  %tel_dtmf count=8 format="????????"
>>     slog "your input: %tel_dtmf"
>>
>> but read() does not seem to get any input
>>
>> ---- snip ----
>> sip/0: state=play, event=400, seq=12   <--- my prompt ends
>> sip/0: state=run, event=100, seq=12
>> sip/0: state=sleep, event=100, seq=12
>> sip/0: state=sleep, event=708, seq=13
>> sip/0: state=run, event=100, seq=13
>> sip/0: state=read, event=100, seq=13    <-- read begins
>> sip/0: state=read, event=400, seq=17
>> sip/0: state=run, event=100, seq=17
>> sip/0: your input: sip/0: state=wait, event=100, seq=17    <-- :(
>> ---- snip ----
>>
>>
>> I had a quick look at the source code but I didn't manage to get what's
>> wrong. Is this a DTMF in/out band issue or a coding one? I know read()
>> differs from input() by the terminating digit abstraction, that's what I
>> want to use.
>>
>> And, by the way, what does 'interdigits' refer to?
>>
>>
>> TIA
>>
> _______________________________________________
> Bayonne-devel mailing list
> [email protected]
> http://lists.gnu.org/mailman/listinfo/bayonne-devel

_______________________________________________
Bayonne-devel mailing list
[email protected]
http://lists.gnu.org/mailman/listinfo/bayonne-devel