Re: input processing issues, solved

Alexandre BOULANGER <[email protected]>
Newsgroups gmane.comp.gnu.bayonne.devel
Message-ID <[email protected]>
Ok I found an answer with no more blank time:
	collect %myvar count=8

I was abused by the "Scripting Bayonne" PDF where the syntax was:
	collect [var=&sym] [count=digits]

so I have always tested things like:
	collect var=%myvar count=8


I've also tried without success the following piece of code, %myvar
keeps a NULL value
	collect count=8
	read %myvar count=8


Thanks for the advice


> I think "collect" is what you would normally use for this case.  Read 
> generally deals with parsing dtmf digits that have already been 
> buffered.  You could either use collect in front of read, as in:
> 
> 	collect count=8
> 	read %myvar count=8 format="????????"
> 
> Or possibly do it in collect itself:
> 
> 	collect %myvar count=8 format="????????"
> 

-- 
Alexandre BOULANGER <[email protected]>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.