Ralph,

Thanks for the reply.

I looked at the Genesys Datasheet for the chip (GL646USB) that is used 
in the HP4850.  I see the register that appears to control the slide 
scanning lamp.

Is there another backend that has support for a similar feature? 
Possibly I could use that as a template to better understand how support 
for this feature might be implemented in the genesys backend.

Thanks again,

Jon


On 7/31/26 11:21 AM, Ralph Little wrote:
> Hi,
> According to our Supported Scanners list 
> (http://www.sane-project.org/sane-supported-devices.html) the genesys 
> backend doesn't yet support the slide scanning feature of this device. 
> It requires additional code to drive the extra hardware involved.
> We don't have an active maintainer for the genesys backend at the 
> moment unfortunately, so I don't know when someone would be able to 
> get to this task in the future. :(
>
> Regards,
> Ralph
>
> On 2026-07-30 20:58, [email protected] wrote:
>>
>> |I recently acquired an HP Scanjet 4850 scanner.  The document 
>> scanning works with no problems.  This particular scanner has a 
>> negative/slide scanning component built in to the lid of the device.  
>> This includes a separate lamp to illuminate the film for scanning.  
>> The lamp in the lid comes when I run a hardware self test procedure 
>> but I have not discovered any way to have the lamp come on when 
>> scanning using sane.
>>
>> Is this capability supported?
>>
>> info about my setup ---
>>
>> HP Scanjet 4850
>>
>> $ scanimage -V
>> scanimage (sane-backends) 1.4.0; backend version 1.4.0
>>
>> genesys backend
>>
>> Fedora Linux 44 (Workstation Edition)
>> Linux 7.1.5-200.fc44.x86_64|
>>
>
--------------FbFMV0eEqX3YgxAsdxV4ygLc
Content-Type: text/html; charset=UTF-8
Content-Transfer-Encoding: 8bit

<!DOCTYPE html>
<html>
  <head>
    <meta http-equiv="Content-Type" content="text/html; charset=UTF-8">
  </head>
  <body>
    <p>Ralph,</p>
    <p>Thanks for the reply.<br>
      <br>
      I looked at the Genesys Datasheet for the chip (GL646USB) that is
      used in the HP4850.  I see the register that appears to control
      the slide scanning lamp.</p>
    <p>Is there another backend that has support for a similar feature?
      Possibly I could use that as a template to better understand how
      support for this feature might be implemented in the genesys
      backend.</p>
    <p>Thanks again,</p>
    <p>Jon</p>
    <p><br>
    </p>
    <div class="moz-cite-prefix">On 7/31/26 11:21 AM, Ralph Little
      wrote:<br>
    </div>
    <blockquote type="cite"
      cite="mid:[email protected]">
      <meta http-equiv="Content-Type" content="text/html; charset=UTF-8">
      Hi,<br>
      According to our Supported Scanners list (<a
        class="moz-txt-link-freetext"
        href="http://www.sane-project.org/sane-supported-devices.html"
        moz-do-not-send="true">http://www.sane-project.org/sane-supported-devices.html</a>)
      the genesys backend doesn't yet support the slide scanning feature
      of this device. It requires additional code to drive the extra
      hardware involved.<br>
      We don't have an active maintainer for the genesys backend at the
      moment unfortunately, so I don't know when someone would be able
      to get to this task in the future. :(<br>
      <br>
      Regards,<br>
      Ralph<br>
      <br>
      <div class="moz-cite-prefix">On 2026-07-30 20:58, <a
          class="moz-txt-link-abbreviated moz-txt-link-freetext"
          href="mailto:[email protected]" moz-do-not-send="true">[email protected]</a>
        wrote:<br>
      </div>
      <blockquote type="cite"
        cite="mid:[email protected]">
        <meta http-equiv="content-type"
          content="text/html; charset=UTF-8">
        <p><code>I recently acquired an HP Scanjet 4850 scanner.  The
            document scanning works with no problems.  This particular
            scanner has a negative/slide scanning component built in to
            the lid of the device.  This includes a separate lamp to
            illuminate the film for scanning.  The lamp in the lid comes
            when I run a hardware self test procedure but I have not
            discovered any way to have the lamp come on when scanning
            using sane.<br>
            <br>
            Is this capability supported?<br>
            <br>
            info about my setup ---<br>
            <br>
            HP Scanjet 4850<br>
            <br>
            $ scanimage -V<br>
            scanimage (sane-backends) 1.4.0; backend version 1.4.0<br>
            <br>
            genesys backend<br>
            <br>
            Fedora Linux 44 (Workstation Edition)<br>
            Linux 7.1.5-200.fc44.x86_64</code></p>