Re: Single shot mode with arbitration support
Daniel Leu <[email protected]>
| Newsgroups | gmane.comp.hardware.bus.can |
|---|---|
| Message-ID | <[email protected]> |
Hi John, > The problem is MilCAN doesn't allow error flags since a bad message retrying > could easily overlap into the next SYNC message window. The architecture of > a MilCAN system is such that the designer plans what messages occur during > each SYNC slot. A node may broadcast only when the SYNC COUNTER was 24. > Another only when 32 and so on. Just wondering where in the MilCAN spec it says that error flags are not allowed. Thanks! Regards, Daniel -- Archives and useful links: http://groups.yahoo.com/group/CANbus Subscribe and unsubscribe at www.vector.com/canlist/ Report any problems to <[email protected]>