RE: Single shot mode with arbitration support
"John Dammyer" <[email protected]>
| Newsgroups | gmane.comp.hardware.bus.can |
|---|---|
| Message-ID | <[email protected]> |
Hi Daniel, See below. Unless it's changed. John From: Doc No. IHSDB-APP-GEN-D-031 Date: March 2003 3.10 Link Layer Re-transmission on Error - Compulsory The LLC sub-layer of the ISO11898 CAN standard includes amongst its functions the retransmission of frames that have been disrupted by errors during transmission. This process can result in an unpredictable number of re-transmissions of the same frame in the event of errors. This function shall be disabled by selecting CAN controllers that provide the capability to disable re-transmissions. Corrective procedures appropriate for the system application may then be executed by the node/device application software -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Daniel Leu Sent: January-17-13 6:09 PM To: [email protected] Subject: Re: [CANLIST] Single shot mode with arbitration support Hi John, > The problem is MilCAN doesn't allow error flags since a bad message > retrying could easily overlap into the next SYNC message window. The > architecture of a MilCAN system is such that the designer plans what > messages occur during each SYNC slot. A node may broadcast only when the SYNC COUNTER was 24. > Another only when 32 and so on. Just wondering where in the MilCAN spec it says that error flags are not allowed. Thanks! Regards, Daniel -- Archives and useful links: http://groups.yahoo.com/group/CANbus Subscribe and unsubscribe at www.vector.com/canlist/ Report any problems to <[email protected]> -- Archives and useful links: http://groups.yahoo.com/group/CANbus Subscribe and unsubscribe at www.vector.com/canlist/ Report any problems to <[email protected]>